Datapak access code – Triton 9610 Operation Manual User Manual
Page 130

TRITON SYSTEMS, INC.
SECTION 5 - MANAGEMENT FUNCTIONS
OPERATION MANUAL - MODEL 9610
5-88
F
UNCTION
: DATAPAK ACCESS CODE
F
ACTORY
D
EFAULT
: OFF
A
CCESS
I
NSTRUCTIONS
:
1.) Select TERMINAL CONFIGURATION from the
MANAGEMENT FUNCTIONS menu.
2.) Select SET TERMINAL PARAMETERS.
3.) Select TELEPHONE.
4.) Select DATAPAK ACCESS CODE.
D
ESCRIPTION
:
NOTE: This feature is only available for the Triton Standard
Canadian version of ATM operating software.
This function allows you to enter the DATAPAK ACCESS CODE,
and to turn the DataPak feature On or OFF. The DATAPAK AC-
CESS CODE is provided by the DataPak processing organization,
and is an identification number which enables the DataPak pro-
cessing organization to correctly identify and route data traffic be-
tween the terminal and the transaction processor.
The current state of the DATAPAK ACCESS CODE feature is
shown as either ON or OFF in the label on the left-hand side of the
display. Press the button next to this label to toggle the state of the
feature between ON and OFF.
IMPORTANT: When using the DATAPAK communications pro-
tocol, ensure the terminal’s Primary and Backup Telephone
Numbers are configured to dial the DataPak processing orga-
nization (NOT the transaction processor!).
E
RROR
C
ONDITIONS
:
If a DATAPAK-based communications network is being used, the
DATAPAK ACCESS CODE feature must turned ON and the code
must be entered correctly to enable message traffic between the
ATM and the processor to take place.