beautypg.com

Triton systems, inc, Multiple amount – Triton 9610 Operation Manual User Manual

Page 113

background image

TRITON SYSTEMS, INC.

5-71

OPERATION MANUAL - MODEL 9610

SECTION 5 - MANAGEMENT FUNCTIONS

F

UNCTION

: MULTIPLE AMOUNT

F

ACTORY

D

EFAULT

: ‘$0.00’

A

CCESS

I

NSTRUCTIONS

:

1.) Select TERMINAL CONFIGURATION from the

MANAGEMENT FUNCTIONS menu.

2.) Select SET TERMINAL PARAMETERS.
3.) Select CASSETTE SETUP.
4.) Choose the MULTIPLE AMOUNT option.

D

ESCRIPTION

:

The MULTIPLE AMOUNT must be set in the Cash Dispenser be-
fore any transactions can be processed. This number is the de-
nomination of the currency installed in the currency cassette. It
can be set to any value, as long as this value is no less than 1/50th
of the MAXIMUM AMOUNT. Typical values might be 10, 20, 50, or
100.

Whenever a withdrawal transaction is performed, the amount en-
tered or selected is compared to the MULTIPLE AMOUNT. If the
entry is not a even multiple of this amount, an error warns the
terminal user and displays the current multiple amount.

E

RROR

C

ONDITIONS

:

If the MULTIPLE AMOUNT is not set correctly, the terminal will
respond by going into Configuration Error 186, BILL SIZE NOT
CONFIGURED CORRECTLY. To correct the error condition enter
the management functions and configure the bill size (MULTIPLE
AMOUNT) to the size of the bill in the cassette.