Flush System – Sump Pump (End
Mount Systems Up To 80 ft.)

It is very important to flush the system. After completing

system assembly, follow steps below in order to flush out
debris from pipes.

1. Open ball valve at end of system. See diagram above.

2. Turn on water. Fill reservoir to fill line.

3. Turn on sump pump to flush out system

4. After flushing system, turn off sump pump.

5. Close ball valve at end of spray line.

6. Close spray line above filter.

7. Clean

filter.

8. Open spray line.

9. Resume normal operation.

Ball Valve

Front View

Drain

Filter

NOTES:

1. Expect about 70 gallons of water per 50

feet of reservoir pipe.

Reservoir and
Pump

Ground

Level

Mega-Cool End Mount, Sump

Pump Flush System

Spray Line Cutoff Valve