Commands

1

2

3

4

5

6

App

Index

IM 04P01B01-17E

4-25

p6 Printout ON/OFF (ON, OFF)

Query

XQ[p1]?

Example Set an absolute timer to timer number 1. Set the

interval to 30 minutes, the reference time to hour
7, reset the data when the timer expires, and
disable printout.
XQ1,ABSOLUTE,30min,07,ON,OFF

Description Each time the interval specified by p3 elapses

from the time specified by p4, the operations set
with p5 and p6 are performed.

When using the relative timer

Syntax

XQ p1,p2,p3,p4,p5
p1 Timer number (1 or 2)
p2 Timer type (RELATIVE)
p3 Interval (fixed to HH:MM format)

HH

Hour (00 to 24)

MM

Minute (00 to 59)

Set the interval in the range 00:01 to 24:00

p4 Reset/not reset the data when the timer

expires (ON/OFF)

p5 Printout ON/OFF (ON, OFF)

Query

XQ[p1]?

Example Set a relative timer to timer number 1. Set the

interval to 1 hour 15 minutes, reset the data
when the timer expires, and disable printout.
XQ1,RELATIVE,01:15,ON,OFF

Description Each time the interval specified by p3 elapses

from the time the computation is started, the
operations set with p4 and p5 are performed.

UN

Changes the assignment of

channels to the recording pen

(pen model, /M1 option).

Syntax

UN p1,p2
p1 Pen number (1 to 4)
p2 Channel number

Query

UN[p1]?

Example Assign computation channel 0A to pen number 4.

UN4,0A

US

Sets the computation error

procedure (/M1 option).

Syntax

US p1,p2
p1 Procedure taken when an error occurs.

+OVER Handle error data as +OVER
−OVER Handle error data as –OVER

p2 Procedure taken when the “input over” is

detected (procedure taken when an “input
over” value is applied to TLOG.SUM or
TLOG.AVE computation)
SKIP

Do not use the data for
computation.

LIMIT Use the limit value given by the

recorder for computation.

Query

US?

Example When the computed result is in error, handle the

error data as +OVER. Use the limit value given
by the recorder for computation instead of the
“input over” value.
US+OVER,LIMIT

YB

Sets the host name and domain

name (/C7 option).

Syntax

YB p1,p2
p1 Host name (up to 64 characters)
p2 Domain name (up to 64 characters)

Query

YB?

Example Set the host name to “ABC” and the domain

name to “recorder.co.jp.”
YBABC,recorder.co.jp

Description The settings specified by this command and

saved using the XE command take effect after
the recorder is power cycled.

YA

Sets the IP address (/C7 option).

Syntax

YA p1,p2,p3
p1 IP address (0.0.0.0 to 255.255.255.255)
p2 Subnet mask

(0.0.0.0 to 255.255.255.255)

p3 Default gateway

(0.0.0.0 to 255.255.255.255)

Query

YA?

Example Set the IP address to 192.168.111.24, the subnet

mask to 255.255.255.0, and the default gateway
to 0.0.0.0.
YA192.168.111.24,255.255.255.0,
0.0.0.0

Description The settings specified by this command and

saved using the XE command take effect after
the recorder is power cycled.

YN

Sets the DNS (/C7 option).

When not using the DNS

Syntax

YN p1
p1 Use/Not use the DNS (OFF)

Query

YN?

Example Do not use the DNS.

YNOFF

When using the DNS

Syntax

YN p1,p2,p3,p4,p5
p1 Use/Not use the DNS (ON)
p2 Address of the primary DNS server

(0.0.0.0 to 255.255.255.255)

p3 Address of the secondary DNS server

(0.0.0.0 to 255.255.255.255)

p4 Domain suffix 1 (up to 64 characters)
p5 Domain suffix 2 (up to 64 characters)

Query

YN?

Example Use the DNS server at 192.168.0.1.

YNON,192.168.0.1

4.5 Basic Setting Commands