Query

SJ[p1]?

Example Enable timer 1 on computation channel 0B. No

sum scale designation.
SJ0B,1,OFF

Description • This command cannot be specified while

computation is in progress.

• About p3
The data for sum computation are sampled

every scan interval. For data with units such
as /s, /min, /h, and /day as in a flow rate, the
data can be summed over the unit time as
shown below. Parameter p3 is valid only for
sum values.

OFF Σ (measured value)
/s

Σ (measured value) × scan interval

/min Σ (measured value) × scan interval/

60

/h

Σ (measured value) × scan interval/

3600

/day Σ (measured value) × scan interval/

(3600×24)

The unit of the scan interval is seconds.

VD

Sets the data display screen.

On screens without detailed parameters

Syntax

VD p1,p2
p1 Screen number (01 to 15)
p2 Display type

4CH bargraph

4-channel bar graph display (pen
model)

6CH bargraph

6-channel bar graph display (µR10000
dot model)

Channel alarm status

Channel alarm status display

Time/Chart speed

Date/Time/Chart speed display

DI/DO

DI/DO status display

STATUS

Status display

System

System display

Batch name

Batch name (/BT1 option)

Lights out

Screen OFF

SKIP

Skip

Query

VD[p1]?

Example Assign the status display to screen 02.

VD02,STATUS

On screens with the displayed channel switching

interval

Syntax

VD p1,p2,p3
p1 Screen number (01 to 15)
p2 Display type

1CH digital

1-channel digital display

2CH digital

2-channel digital display

4CH digital

4-channel digital display

6CH digital

6-channel digital display (dot model)

12CH digital

12-channel digital display (µR20000
12, 18 and 24 dot model)

1CH digital+1CH bargraph

1-channel digital display + 1 channel
bar graph display

1CH digital+4CH bargraph

1-channel digital display + 4 channel
bar graph display (pen model)

2CH digital+2CH bargraph

2-channel digital display + 2 channel
bar graph display

Tag_1CH digital

1-channel digital display (tag)

Tag_2CH digital

2-channel digital display (tag)

Tag_1CH digital+1CH bargraph

1-channel digital display + 1 channel
bar graph display (tag)

Tag_1CH digital+4CH bargraph

1-channel digital display + 4 channel
bar graph display (tag, pen model)

p3 Displayed channel switching interval

MANUAL Fixed display channels, data

update rate (pen model): 2 s,
data update rate (dot model):
scan interval

AUTO1S Switch the displayed channels

and data every second.

AUTO2S Switch the displayed channels

and data every 2 seconds.

AUTO3S Switch the displayed channels

and data every 3 seconds.

AUTO4S Switch the displayed channels

and data every 4 seconds.

AUTO5S Switch the displayed channels

and data every 5 seconds.

Query

VD[p1]?

4.4 Setting Commands

This manual is related to the following products: