4-43

Commands

IM MV1000-17E

1

2

3

4

5

6

7

App

Index

4.10 Output Commands (Special

Response Commands)

*I

Transmits instrument

information

Syntax

*I

Description Transmits the maker, model, serial number, and

firmware version in a comma-separated ASCII
text with a terminator at the end.

Example

YOKOGAWA,MV1000,99AA0123,F1.01

4.11 Maintenance/Test

Commands (available when

using the maintenance/

test server function via the

Ethernet interface)

close Disconnects the connection

between other instruments

Syntax

close,p1,p2:p3
p1 MV port (1 to 65535)
p2 PC IP address

(0.0.0.0 to 255.255.255.255)

p3 PC port (0 to 65535)

Example

close,34159,192.168.111.24:1054

E0

Description You cannot use this command to disconnect

a server port. You cannot use this command
to disconnect a port of an instrument that is
being controlled. Use the quit command for this
purpose.

con

Transmits connection

information

Syntax

con

Example

con

EA

00/00/00 12:34:56

Active connections

Proto Local Address Foreign Address State

TCP 192.168.111. 24:34159 192.168.111. 24:1053 ESTABLISHED

TCP 0. 0. 0. 0:34155 0. 0. 0. 0:

0 LISTEN

TCP 0. 0. 0. 0:34159 0. 0. 0. 0:

0 LISTEN

TCP 0. 0. 0. 0:34150 0. 0. 0. 0:

0 LISTEN

EN

TCP
The protocol used.
Local Address
The MV socket address.
Displays “IP address:port number.”
Foreign Address
The destination socket address.
Displays “IP address:port number.”
State
Connection state.
ESTABLISHED
Connection established.

eth

Transmits Ethernet statistics

Syntax

eth

Example

eth
EA
00/00/00 12:34:56

4.10 Output Commands (Special Response Commands)/

4.11 Maintenance/Test Commands