2 pulse output, Pulse output -28 – Yokogawa FieldMate User Manual
Page 60
<6 OPERATION>
6-28
IM 01R01A11-01EN
6.3.2
Pulse Output
This item checks the pulse output from the converter.
Check the Suffi x Code of AXF converter or AXF integral fl owmeter.
■ Without optional code EM, see “(A) Pulse Output (without optional code EM)”.
■ With optional code EM, see “(B) Active Pulse Output (with optional code EM)”.
4
1
2
3
5
F060306.ai
Figure 6.3.6 “Pulse Output” Screen
Table 6.3.4 “Pulse Output” Screen
Item
No.
Item Name
Description
1
Connection diagram
Shows the connection diagram on another screen. The diagram is any of
those in
Figure 6.3.9 or Figure 6.3.13 depending on the case.
2
Setting Value
Selects and shows the setting pulse value.
3
Measured (pps)
Shows the measured value. Enter the measured value manually.
4
Output (*1)
in Output Selection
Outputs the pulse.
By clicking “Output” after selecting “Pulse”, the pulse with the value of
“Setting value (2)” is transferred to AXF.
(Only when Verifi cation Tool is in “online” mode)
5
Exit
In Output Selection
Stops pulse output and enables other operations.
(Only when Verifi cation Tool is in “online” mode)
*1: When the AXF protect function is set to “Protect”,
Figure 3.2.2 is displayed after clicking “Output”. Follow 3.2.2.