3 flow transducer block, Flow transducer block -6 – Yokogawa EJX930A User Manual
Page 70
<9. Parameter Lists>
9-6
IM 01C25R03-01E
Relative
Index Index
Parameter Name
Factory Default
Write
Mode
Explanation
95
2095 DIAG_COUNT
3
AUTO
Used for ILBD. Refer to A8.2.12
96
2096 REFERENCE_TIME
0x00000000
AUTO
Used for ILBD. Refer to A8.2.12.
97
2097 REFERENCE_FDP
0x00, 0
AUTO
Used for ILBD. Refer to A8.2.12.
98
2098 REFERENCE_FSPL
0x00, 0
AUTO
Used for ILBD. Refer to A8.2.12.
99
2099 REFERENCE_FSPH
0x00
AUTO
Used for ILBD. Refer to A8.2.12.
100
2100 REFERENCE_BLKF
0x00
AUTO
Used for ILBD. Refer to A8.2.12.
101
2101 REFERENCE_DPAVG 0x00
AUTO
Used for ILBD. Refer to A8.2.12.
102
2102 VALUE_TIME
—
Used for ILBD. Refer to A8.2.12.
103
2103 VALUE_ FDP
—
Used for ILBD. Refer to A8.2.12.
104
2104 VALUE_ FSPL
—
Used for ILBD. Refer to A8.2.12.
105
2105 VALUE_ FSPH
—
Used for ILBD. Refer to A8.2.12.
106
2106 VALUE_ BLKF
—
Used for ILBD. Refer to A8.2.12.
107
2107 VALUE_DPAVG
—
Used for ILBD. Refer to A8.2.12.
108
2108 RATIO_FDP
—
Used for ILBD. Refer to A8.2.12.
109
2109 RATIO_FSPL
—
Used for ILBD. Refer to A8.2.12.
110
2110 RATIO_FSPH
—
Used for ILBD. Refer to A8.2.12.
111
2111 CRATIO_FDP
—
Used for ILBD. Refer to A8.2.12.
112
2112 NRATIO_FDP
—
Used for ILBD. Refer to A8.2.12.
113
2113 DIAG_APPLICABLE
0
—
Used for ILBD. Refer to A8.2.12.
114
2114 FLG_TEMP_VAL
—
Used for Heat Trace monitoring. Refer to A8.2.12.
115
2115 FLG_TEMP_RANGE
-50.0 to 130.0°C
—
Used for Heat Trace monitoring. Refer to A8.2.12.
116
2116 FLG_TEMP_COEFF
0
AUTO
Used for Heat Trace monitoring. Refer to A8.2.12.
117
2117 FLG_TEMP_PRI
1
AUTO
Used for Heat Trace monitoring. Refer to A8.2.12.
118
2118 FLG_TEMP_H_LIM
130
AUTO
Used for Heat Trace monitoring. Refer to A8.2.12.
119
2119 FLG_TEMP_L_LIM
-50
AUTO
Used for Heat Trace monitoring. Refer to A8.2.12.
120
2120 FLG_TEMP_ALM
—
Used for Heat Trace monitoring. Refer to A8.2.12.
121
2121 TET_KEY1
—
Not used for EJX multivariable transmitter.
122
2122 TET_KEY2
—
Not used for EJX multivariable transmitter.
123
2123 TET_KEY3
—
Not used for EJX multivariable transmitter.
124
to
139
2124
to
2139
TEST1 to 16
—
Not used for EJX multivariable transmitter.
Note: Refer to A8.2.1
9.3 FLOW Transducer Block
Relative
Index Index
Parameter Name
Factory Default
Write
Mode
Explanation
0
2300 Block Header
TAG: “FTB”
Block
Tag=O/S
Information, such as Block Tag, DD Revision and Execution
Time, relating to this block.
1
2301 ST_REV
—
—
This parameter expresses the revision level of the transducer
block setting parameters. This revision is updated when the
setting value is changed. This parameter is used, for example,
to investigate if parameters have been changed.
2
2302 TAG_DESC
AUTO
Universal parameter for storing comments to describe the
content of tags.
3
2303 STRATEGY
1
AUTO
Universal parameter intended for use when the host system
separates the function blocks.
4
2304 ALERT_KEY
1
AUTO
This is one of the universal parameters and is key information
for identifying where an alert has occurred. Normally, the host
system identifies specific area in a plant covered by a specific
operator, and this information is used for selecting only the
required alert.
5
2305 MODE_BLK
AUTO
AUTO
This universal parameter expresses the operation mode of the
block, and comprises the Actual mode, Target mode, Permit
mode, and Normal mode.
6
2306 BLOCK_ERR
0x0000
—
Indicates the error state relating to the self block.
7
2307 UPDATE_EVT
—
—
Indicates the content of an event when an update event has
occurred.
8
2308 BLOCK_ALM
—
—
Indicates the content of an error that has occurred in the block.