beautypg.com

Watlow Series 96 User Manual

Page 65

background image

Wa t l o w S e r i e s 9 6

A p p e n d i x

A . 6

Communications

• EIA/TIA-485 or EIA/TIA-232
• Opto-isolated
• Modbus

TM

RTU protocol

• 1200, 2400, 4800, 9600, 19200 baud rates
• 32 maximum units can be connected (with additional 485

repeater hardware, up to 247 units may be connected)

Accuracy

• Input ranges

Type J:

32

to

1382°F

or

0

to

750°C

Type K:

-328

to

2282°F

or

-200

to 1250°C

Type T:

-328

to

662°F

or

-200

to

350°C

Type N:

32

to

2282°F

or

0

to 1250°C

Type E:

-328

to

1470°F

or

-200

to

900°C

Type C(W5):

32

to

4200°F

or

0

to 2315°C

Type D(W3):

32

to

4200°F

or

0

to 2315°C

Type PTII:

32

to

2540°F

or

0

to 1393°C

Type R:

32

to

2642°F

or

0

to 1450°C

Type S:

32

to

2642°F

or

0

to 1450°C

Type B:

1598

to

3092°F

or

870

to 1700°C

DIN:

-328

to

1472°F

or

-200

to

800°C

JIS:

-328

to

1166°F

or

-200

to

630°C

Process:

-1999 to

9999 units

Thermocouple Inputs

• Calibration accuracy ±0.1% of span ±1°C at standard

conditions
Exceptions:
Type T; 0.12% of span for -200°C to -50°C,
Types R and S; 0.15% of span for 0°C to 100°C
Types B; 0.24% of span for 870°C to 1700°C

• Accuracy span: 1,000°F/540°C minimum
• Temperature stability: ±0.1 degree per degree change in

ambient

RTD Inputs

• Calibration accuracy ±0.1% of span ±1°C at standard

conditions

• Accuracy span: 1,000°F/540°C minimum
• Temperature stability: ±0.05 degree per degree change in

ambient

Process Inputs

• Voltage input ranges

Accuracy ±10mV ±1 LSD at standard conditions
Temperature stability ±100ppm/°C maximum

• Milliamp input ranges

Accuracy ±20µA ±1 LSD at standard conditions

Temperature stability ±100ppm/°C maximum

Agency Approvals

• UL 916 Listed file Number E185611; c-UL Approved,
• UL CCN QQXY, QQXY7 Process Control Equipment
• CE and NEMA 4X approved.

Modbus™ is a trademark of AEG Schneider Automation.

UL® is a registered trademark of the Underwriter’s Laboratories, Inc.

Terminals

• Touch safe
• 22 to 12 AWG

Power

• 100-240V

(ac/dc) +10%; -15%; 50/60Hz, ±5%

• 24-28V

(ac/dc) +10%; -15%; 50/60Hz, ±5%

• 7.0VA maximum power consumption
• Data retention upon power failure via nonvolatile memory

Operating Environment

• 32 to 149°F, 0 to 65°C
• 0 to 90% RH, non-condensing
• Storage temperature: -40 to 185°F, -40 to 85°C

Dimensions

• Width 2.05 in. or 52mm
• Height 2.05 in. or 52mm
• Length 4.2 in. or 107mm
• Depth behind panel surface 3.875 in. or 98.4mm
• Approximate controller weight 0.4 lbs (0.2 kg)

Allowable Operating Ranges

Type J:

1.0

32

to

1,500°F

or

0

to

815°C

0.1

32.0

to

999.9°F

or

0.0

to 815.0°C

Type K:

1.0 -454

to

2,500°F

or

-270

to 1,370°C

0.1 -199.9

to

999.9°F

or

-199.9

to 999.9°C

Type T:

1.0 -454

to

750°F

or

-270

to

400°C

0.1 -199.9

to

750.0°F

or

-199.9

to 400.0°C

Type N:

1.0

32

to

2,372°F

or

0

to 1,300°C

0.1

32.0

to

999.9°F

or

0.0

to 999.9°C

Type E:

1.0 -454

to

1,470°F

or

-270

to

800°C

0.1 -199.9

to

999.9°F

or

-199.9

to 800.0°C

Type C:

1.0

32

to

4,200°F

or

0

to 2,315°C

0.1

32.0

to

999.9°F

or

0.0

to 999.9°C

Type D:

1.0

32

to

4,200°F

or

0

to 2,315°C

0.1

32.0

to

999.9°F

or

0.0

to 999.9°C

Type PTII: 1.0

32

to

2,543°F

or

0

to 1,395°C

0.1

32.0

to

999.9°F

or

0.0

to 999.9°C

Type R:

1.0

32

to

3,200°F

or

0

to 1,760°C

Type S:

1.0

32

to

3,200°F

or

0

to 1,760°C

Type B:

1.0

32

to

3,300°F

or

0

to 1,816°C

RTD (DIN) 1.0 -328

to

1,472°F

or

-200

to

800°C

0.1 -199.9

to

999.9°F

or

-199.9

to 800.0°C

RTD (JIS) 1.0 -328

to

1,166°F

or

-200

to

630°C

0.1 -199.9

to

999.9°F

or

-199.9

to 630.0°C

Process

-1,999

to

9,999 units

Note: These specifications are subject to change without prior notice.

Event &

Universal

Remote

232/485

Input

Set Point Control

Alarm

Retransmit

Comm

Input 1
Input 2
Output 1
Output 2
Output 3
Output 4

Functionality Matrix