the way the controller was programmed at [EtypE] / {Sound]:

With Sound set to 0: The controller automatically switches to idle, where the con-
troller maintains the temperatures at set point and does not run time. [`idle] or
time of day will appear on the display. The menu key indicator light will flash slow-
ly.

With Sound set to 1, 2, or 3: [``End] will appear on the display and an audible tone
will be emitted. The menu key indicator light will flash rapidly. You can acknowl-
edge and silence the tone by pressing the active menu key or it will time out in 1 to
20 seconds and go into idle. The menu key indicator light will flash slowly.

With Sound set to 4 or 5: [``End] will appear on the display and the menu key
indicator light will flash rapidly. You must acknowledge the audible tone by pressing
the active menu key. Once acknowledged the tone is silenced and the controller goes
into idle. The menu key indicator light will flash slowly.

5.

Remove the food from the fryer. The controller will continue to regulate at the last
set point. The menu indicator light will flash slowly.

6. To repeat cooking, repeat steps 1 through 5.

Cancel a Menu

Canceling a menu stops controller operation completely. The controller does not main-
tain set point temperatures or run time. Users may cancel a menu in order to run
another one, to stop menu operation for any reason, or when preparing to shut off the
fryer.

Press the active menu key for 2 seconds.

Heat outputs will switch off. Heat output indicator lights will switch off. The display
presents [`idle] or the time of day will appear on the display.

Change or Restart Menus

• With the controller in idle, press the key for the menu you want to run.

Temperature Alarms

The controller will alert you to temperature alarm conditions if they occur. If an alarm
occurs, take action as determined by your supervisor. See the Appendix in the Hardware
& Software Setup Guide
for a Troubleshooting Chart and a summary of temperature
alarms.

Errors

The controller will alert you to errors if they occur. Errors are critical problems that
shut down the unit. If an error occurs, an error message will appear on the display. You
should switch off the power and call for service.

See the Appendix in the Hardware & Software Setup Guide for a Troubleshooting Chart
and a summary of errors.