beautypg.com

Initial preheat, Preheat, Idle – Watlow MINICHEF Deep Fat Fryer Application User Manual

Page 63: 100f, Ready, Pre-`] [`heat, 50`f

background image

A p p l i c a t i o n 1 5

Wa t l o w M i n i C h e f 2 0 0 0

6 1

Five Second Timeout

When using the up or down keys to change a value, if you do not press any key for 5
seconds, the controller will automatically be set to the last value on the display and
return to [`idle].

Initial Preheat

At power-up, the unit will preheat to the temperature value set in the Configuration
Mode [seTUp] / [Ready]. The display will show [prE-`] [`Heat] followed by oil
temperature as the oil heats up.

When the unit reaches initial preheat temperature, [ready] will flash once on the dis-
play and an audible tone will sound for 2 seconds. Then [`idle] will appear on the dis-
play. If the Real-time Clock option is installed and [SEtUp] / [Cloc`] is set to
[``yes], the time of day will appear on the display.

If the preheat condition is met at power-up, the controller goes directly to idle, and does
not display [rEAdy] or sound an audible tone.

Preheat

If in the Configuration Mode [SEtUP] / [ready] has been set to yes, the controller will
detect temperatures and preheat to operating temperature (above relative set point
minus the ready band) as required.

Activate the current menu by pressing the Start/Stop key.

If the fryer is not at operating temperature, it will preheat. Meanwhile:

The word [Pre-`] [`Heat] will appear on the display for a few moments. The
Start/Stop key indicator light will flash slowly. The temperature of Channel 1 will
be displayed until the operating temperature is reached.

The heat output indicator light - G, just below the display- will light up whenever
the controller is calling for heat.

When the fryer is at operating temperature (above relative set point minus the
ready band) [ready] will appear on the display and the Start/Stop key indicator
light will flash rapidly. You are now ready to cook with the active menu.

If the fryer is at operating temperature, the display goes directly to [ready] with-
out indicating preheat or temperature.

A

B

D

E

C

F

G

H

M

INI

C

HEF

2000

[`idle]

Edit

Accept

Back-Up

Exit

SLOW

FLASH

AT OPERATING TEMPERATURE

(PREHEAT CONDITION MET)

RAPID

FLASH

B

D

E

C

F

M

INI

C

HEF

2000

[100f`]

Edit

Accept

Back-Up

Exit

B

D

E

C

F

M

INI

C

HEF

2000

[ready]

Edit

Accept

Back-Up

Exit

G

H

G

H

A

A

[pre-`] [`Heat]

D

E

C

F

M

INI

C

HEF

2000

[`50`f]

Edit

Accept

Back-Up

Exit

D

E

C

F

M

INI

C

HEF

2000

[ready]

Edit

Accept

Back-Up

Exit

A

B

G

H

A

B

G

H

D

E

C

F

M

INI

C

HEF

2000

[`idle]

Edit

Accept

Back-Up

Exit

A

B

G

H