beautypg.com

Configuration mode quick reference – Watlow MINICHEF Deep Fat Fryer Application User Manual

Page 39

background image

A p p l i c a t i o n 1 3

Wa t l o w M

I N I

C

H E F

2 0 0 0

3 7

Configuration Mode Quick Reference

These are the functions, parameters and values included in the Configuration Mode for
this application. You must select Application 13 to access them. For directions, see the
Hardware & Software Setup Guide. The Appendix of that guide includes an explanation
of all parameters and values.

Function

Parameter

Value

Your settings

[Etype] Equipment-Type

[appl`] Application Number

1 - 28

13

[a_Loc] Application Number

Yes, No

Security Lock

[Sound] Audible Alarm Sound

0 - 5

[ptine] Pressure Release Time

1 - 120 seconds

[preHt] Initial Preheat Temperature

Range low to range high

[melt] Oil Melt Cycle

On, Off

[SEtUP] Setup

[`З_П`] Temperature Display Format

ºC or ºF

[time] Time Display Format

MMM:SS, HH:MM, H:MM:SS
(H=Hours, M=Minutes, S=Seconds)

[Chirp] Key Chirp

On, Off

[loc``] Menu Security Lock

Yes, No

[tc```] Thermocouple Type

J, K (shown as [````H]), E

[rtd``] RTD Curve

DIN, JIS

[tconp] WatCurve

TM

Temperature On,

Off

Compensation

[Ofst1] Temperature Offset, Channel 1

-99 to 99ºF (-55 to 55ºC)

[tr`lo] Temperature Range Low

0ºF (-18ºC) for RTD inputs
32ºF (0ºC) for tc inputs to [tr`Hi]

[tr`Hi] Temperature Range High

[tr`lo] to 1200ºF (649ºC)

[ready] Preheat Ready Feature

Yes, No

[rband] Ready Band

1 to 1200ºF (649ºC)

[Cloc`] Real Time Clock Display

Yes, No

[plOSS] Power Loss Menu Resume

Yes, No

[al``1] Alarms for channel 1

None, Dev, Proc, Both

[aL`P1] Absolute Process Alarm 1

100 to 1200ºF (38 to 649ºC)

[aLdL1] Low Deviation Alarm 1

-999 to 0ºF (-555 to 0ºC)

[aLdH1] High Deviation Alarm 1

0 to 999ºF (0 to 555ºC)

[tHErl] Thermal

[tyPE`] Temperature Control Type

PID, On-Off

[HYSt1] Hysteresis 1

1 to 99ºF (1 to 55ºC)

[Pid`U] PID Units

SI, US

[tune1] Auto-tuning 1

on, OFF

[ProP1] Proportional Band 1

1 to 999ºF (1 to 555ºC)

[rSEt1] Reset (integral) Gain 1

0.00 to 9.99 repeats/minute

[int`1] Integral Gain 1

0.00 to 99.99 minutes/repeat

[rAtE1] Rate (derivative) Gain 1

0.00 to 9.99 minutes

[dEr`1] Derivative Gain 1

0.00 to 9.99 minutes

[CYcL1] PID Cycle Time 1

1 to 60 seconds

[`diag] WatHelp

Used for equipment troubleshooting and testing. Not used when programming. See the Hardware

Diagnostics

& Software Setup Guide..