Program mode quick reference – Watlow MINICHEF Deep Fat Fryer Application User Manual
Page 6
![background image](/manuals/359138/6/background.png)
4
■
Wa t l o w M
I N I
C
H E F
2 0 0 0
A p p l i c a t i o n 1 0
Program Mode Quick Reference
These are the functions, parameters and values included in the Program Mode for this
application. You must select Application 10 to access them. For menu programming direc-
tions, see the Hardware & Software Setup Guide. The Appendix of that guide includes a
detailed explanation of all parameters and values.
Function
Parameter
Value
Your Settings
[M`__] Menu
[Stpt1] Set point 1
Format varies based on configuration.
Numbers 1 - 4
Temperature of channel 1.
[TiNe1] Time 1
Format varies based on configuration.
Menu run time.
Setting at 0 invalidates selected menu.
[alarn] Mid-menu alarm setting.
[Stir], [Add], [Flip],
[Turn], [Alert], [None]
[atine] Mid-menu alarm time.*
0 to [TiNe1].
*Note: Applies only when the alarm is not set to [`none].
Auto-tuning note:
Before auto-tuning Application 10, Set Point 1 of Menu 1 must first be set to a value that
is typical of your application. (See the Hardware & Software Setup Guide for information
on programming menus.) Then set [tHErL] / [tunE1] to [```on]. After you accept this
[```on] setting, the display will present [`tunE] when the auto-tuning is taking place.
The controller will cancel the auto-tuning process if it cannot be completed in 80 min-
utes. You can cancel the auto-tuning process at any time be pressing either key C or Key
D and accepting [``Off] when it appears.