Configuration Mode Quick Reference
These are the functions, parameters and values included in the Configuration Mode for
this application. You must select Application 11 to access them. For directions, see the
Hardware & Software Setup Guide. The Appendix of that guide includes an explanation
of all parameters and values.
Function
Parameter
Value
Your Settings
[Etype] Equipment-Type
[appl`] Application Number
1 - 28
11
[a_Loc] Application Number
Yes, No
Security Lock
[Sound] Audible Alarm Sound
0 - 5
[btine] Basket Travel Time
0 - 30 seconds
[idle1] Channel 1 Idle Temperature
Temperature range low to
range high
[idle2] Channel 2 Idle Temperature
Temperature range low to
range high
[Melt] Oil Melt Temperature
On, Off
[SEtUP] Setup
[`З_П`] Temperature Display Format
ºC or ºF
[time] Time Display Format
MMM:SS, HH:MM, H:MM:SS
(H=Hours, M=Minutes, S=Seconds)
[Chirp] Key Chirp
On, Off
[loc``] Menu Security Lock
Yes, No
[tc```] Thermocouple Type
J, K (shown as [````H]), E
[rtd``] RTD Curve
DIN, JIS
[tconp] WatCurve
TM
Temperature On,
Off
Compensation
[Ofst1] Temperature Offset, Channel 1 -99 to 99ºF (-55 to 55ºC)
[tr`lo] Temperature Range Low
0ºF (-18º C) for RTD inputs,
32ºF (0ºC) for tc inputs to [tr`HI]
[tr`HI] Temperature Range High
[tr`lo] to 1200ºF (649ºC)
[ready] Preheat Ready Feature
Yes, No
[rband] Ready Band
1 to 1200ºF (649ºC)
[Cloc`] Real Time Clock Display
Yes, No
[plOSS] Power Loss Menu Resume
Yes, No
[al``1] Alarms for channel 1
None, Dev, Proc, Both
[aL`P1] Absolute Process Alarm 1
100 to 1200ºF (38º to 649ºC)
[aLdL1] Low Deviation Alarm 1
-999 to 0ºF (-555 to 0ºC)
[aLdH1] High Deviation Alarm 1
0 to 999ºF (0 to 555ºC)
[tHErl] Thermal
[tyPE`] Temperature Control Type
PID, On-Off
[HYSt1] Hysteresis 1
1 to 99ºF (1 to 55ºC)
[Pid`U] PID Units
SI, US
[tune1] Auto-tuning 1
on, OFF
[ProP1] Proportional Band 1
1 to 999ºF (1 to 555ºC)
[rSEt1] Reset (integral) Gain 1
0.00 to 9.99 repeats/minute
[int`1] Integral Gain 1
0.00 to 99.99 minutes/repeat
[rAtE1] Rate (derivative) Gain 1
0.00 to 9.99 minutes
[dEr`1] Derivative Gain 1
0.00 to 9.99 minutes
[CYcL1] PID Cycle Time 1
1 to 60 seconds
[`diag] WatHelp
Used for equipment troubleshooting and testing. Not used when programming. See the Hardware
Diagnostics
& Software Setup Guide..