Chapter 1 Specifications Check
22
IA Net
XSEL-R/S
1.2 Basic Specifications List
Item
Description
Remarks
Communication System Half-duplex multi-drop
Insulation with pulse transformers
Baud Rate
12Mbps
ņ
Number of Connectable
Units
64 units at maximum
There are restrictions in the number of
units depending on the system
construction of the network.
[Refer to Chapter 3 Operation]
Occupied Memory Units 1 to 4 stations
XSEL : 1 to 4 stations to be occupied
Expansion I/O Unit : 4 stations to be
occupied
Shared Memory
Capacity
256 words
1 station (4 words) × 64 areas
Cycle Time
(Note 1)
0.102msec
(when 2 units connected) to䎃
2.365msec
(when 64 units connected)
Refer to 3.1.3 Regarding Communication
Cycle Time
Cable
Dedicated Cable
(CB-RS-IAN * * *)
Shielded two-cored twisted pair cable
Total Cable Length
100m
ņ
Terminal Resistance
External mount
100: (1/2W) necessary on both terminals
XSEL Side MCDN1.5/3-G1-3.5P26THR
Manufactured by PHOENIX CONTACT
Connector
Cable Side FMC1.5/3-ST-3.5
Manufactured by PHOENIX CONTACT
Note1 The calculation for IA Net communication cycle time is based on the last station number.
When 2 units connected(= final station No.1)
{(1+152) Ч (1 + 3) Ч 2} / 12000 = 0.102ms
When 64 units connected(= final station No.63)
{(63 + 152) Ч (63 + 3) Ч 2} / 12000 = 2.365ms