beautypg.com

3 s8ss, 1 standard type, External dimensions 60 – IAI America LSA-S10SS User Manual

Page 66: S8ss standard type

background image

8. External Dimensions

60

8.3 S8SS

8.3.1 Standard Type

S8SS Standard Type

No.

st

L

A

B

C

D

E

Weight (kg)

1

60

338

1

32

8

132

168

4.4

2

120

398

1

92

8

192

193

4.7

3

180

458

1

152

8

252

218

5.1

4

240

518

2

12

12

312

243

5.4

5

300

578

2

72

12

372

268

5.8

6

360

638

2

132

12

432

293

6.1

7

420

698

2

192

12

492

318

6.5

8

480

758

3

52

16

552

343

6.9

9

540

818

3

112

16

612

393

7.2

10

600

878

3

172

16

672

418

7.6

11

660

938

4

32

20

732

443

7.9

12

720

998

4

92

20

792

468

8.3

13

780

1058

4

152

20

852

493

8.7

14

840

1118

5

12

24

912

543

9.0

15

900

1178

5

72

24

972

568

9.4

16

960

1238

5

132

24

1032

593

9.7

17

1020

1298

5

192

24

1092

618

10.1

18

1080

1358

6

52

28

1152

643

10.4

19

1140

1418

6

112

28

1212

693

10.8

20

1200

1478

6

172

28

1272

718

11.2

21

1260

1538

7

32

32

1332

743

11.5

22

1320

1598

7

92

32

1392

768

11.9

23

1380

1658

7

152

32

1452

793

12.2

24

1440

1718

8

12

36

1512

843

12.6

25

1500

1778

8

72

36

1572

868

12.9

26

1560

1838

8

132

36

1632

893

13.3

27

1620

1898

8

192

36

1692

918

13.7

5

0

+0.012

4

2.7

1.8

5.5

3.3 5.8

50

50

(D)

50

35

(B)

35

ME

SE

ME

L(st+278)

5

(45)

59

st

160

59

(45)

5

25

50

25

80

(max15)

E

16

52

16

75

Cable

6

15

6

21

16.5

75

8

52

8

43

74

91

100 97

86

35

80

32

60

80

140

1

99

100

165

85

80

19

14

15

24

49

40

14 19

Reference

surface

Cable track for user (S type)

Cable track for user (M type)

Detail view of G

Detail view of F

M3 T-slot

(F)

2-φ4H7, reamed depth 5

2-slot,

depth 5 (G)

C-M5, depth 10

A×100

P

A×100

P

HOME

65±0.02

4-M5, depth 10

2-φ4H7, depth 8

(Reamer pitch: ±0.02)

4-M3, depth 5

*The slider goes up the ME

in the home-return operation.

Pay attention to interference

to peripherals.

ME

: Mechanical end

SE

: Stroke end

Cable Track for User Wiring

Section Dimensions (S type)

Cable Track for User Wiring

Section Dimensions (M type)

60