4 installation surface – IAI America LSA-S10SS User Manual
Page 43
![background image](/manuals/350272/43/background.png)
2. Installation
37
2.3.4 Installation Surface
• For the platform to install the actuator, ensure the structure that possesses enough stiffness to
avoid vibration being generated.
• Install the actuator on a machined surface or other flat surface of equivalent accuracy. The
flatness of the installation surface must be 0.05 mm/m or less.
• Provide sufficient space to allow for maintenance work.
• The side and bottom surfaces of the actuator base provide reference surfaces used for alignment
of slider travel.
• If you require higher traveling accuracy, install the actuator using these reference surfaces.
Reference surface
Reference surface
Drawings for Standard Type
As shown above, each side surface of the base provides a reference surface used for alignment
of slider travel. If you require higher traveling accuracy, therefore, install the actuator with
reference to either side surface of the base.
When installing the actuator on the frame using the base reference surfaces, provide the necessary
machining by following the drawing below.
Model
Dimension A (mm)
S6, S8
1.5 ~ 2 or less
S10
1.5 ~ 3 or less
A
R0.3 or less