2. Specification
23
(2) SSPA
Static allowable load moment [Nxm]
Dynamic allowable load moment
[Nxm]
Size
Ma
Mb
Mc
Ma
Mb
Mc
Allowable overhang
load [L]
SXM
190
190
530
36
36
98
Ma direction: 450
Mb or Mc direction: 450
MXM
470
470
1210
90
90
230
Ma direction: 600
Mb or Mc direction: 600
LXM
750
750
1850
138.8
138.8
334.5
Ma direction: 750
Mb or Mc direction: 750
L [mm]
SXM
45.0
MXM
48.5
LXM
50.5
Caution: Make sure the load installed on the actuator is not longer than the allowable overhang load length
(L). If the load is longer than L, vibration may occur or the settling time may increase depending on
the position of center of gravity position or weight of the work part.
If a load moment exceeding the allowable load moment is applied, not only the life of the guide will
become shorter but vibration or longer settling time may also result.
Mb or Mc direction
Direction of moment
Direction of allowable overhang
Ma direction
Mb direction
Mc direction
Ma direction
Reference position for
moment calculation
L
Reference position