beautypg.com

IAI America RCS2-A6R User Manual

Page 33

background image

2. Installation

27

2.2 Installation and Storage • Preservation Environment

[1] Installation Environment

The actuator should be installed in a location other than those specified below.

In general, the installation environment should be one in which an operator can work without

protective gear.

Also provide sufficient work space required for maintenance inspection.

Where the actuator receives radiant heat from strong heat sources such as heat treatment

furnaces

Where the ambient temperature exceeds the range of 0 to 40�C

Where the temperature changes rapidly and condensation occurs

Where the relative humidity exceeds 85% RH

This actuator possesses the water durability of IP67 protection structure.

Where the actuator receives direct sunlight

Where the actuator is exposed to corrosive or combustible gases

Where the ambient air contains a large amount of powder dust, salt or iron (at level

exceeding what is normally expected in an assembly plant)

Where the actuator receives impact or vibration


If the actuator is used in any of the following locations, provide sufficient shielding measures:

Where noise generates due to static electricity, etc.

Where the actuator is subject to a strong electric or magnetic field

Where the actuator is subject to ultraviolet ray or radiation

[2] Storage • Preservation Environment

The storage and preservation environment should comply with the same standards as

those for the installation environment. In particular, when the machine is to be stored for a

long time, pay close attention to environmental conditions so that no dew condensation

forms.

Unless specially specified, moisture absorbency protection is not included in the package

when the machine is delivered. In the case that the machine is to be stored and preserved

in an environment where dew condensation is anticipated, take the condensation

preventive measures from outside of the entire package, or directly after opening the

package.

For storage and preservation temperature, the machine withstands temperatures up to

60�C for a short time, but in the case of the storage and preservation period of 1 month or

more, control the temperature to 50�C or less.

Storage and preservation should be performed in the horizontal condition. In the case it is

stored in the packaged condition, follow the posture instruction if any displayed on the

package.