REMOVING SPRAY APPLICATOR

FROM THE REAR MANIFOLD

ASSEMBLY

(See Figure 15)

Anytime service is required within the applicator

shroud, the applicator should be removed from the

robot mounting plate assembly. After the applicator

is removed from the robot, always move to a clear,

clean work area to remove the applicator shroud and

begin servicing.

1. Purge all fluid from the system and blow lines

dry with pushout air before the applicator is re-

moved.

2. All pressures must be removed, both air and

fluid, before removing the applicator. Fluid pressure

can be removed by actuating the applicator trigger

with the fluid regulator open.

3. Turn off the power supply to the applicator.

4. Remove applicator from robot by turning the re-

taining ring [6] counter-clockwise from the manifold

robot mounting plate [2] (see Figure 15).

5. Remove spray head [5] (Figure 15) as previously

described in Figure 13a.

Spray Applicator Disassembly

(See Figures 15, 16, and 17)

6. Remove the four (4) screws [7] from mounting block

[3] and pull the block out of the upper manifold [4]

as shown in Figure 15.

7. Remove and inspect the o-rings [2, 19, and 20] on

the upper manifold [18]. Replace if necessary (see

Figure 16).

8. Remove mounting ring [13] by pulling straight up

as shown in Figure 16.

9. Remove the five (5) screws [11] from the

bottom of the mounting plate [12] (see Figure 16).

10. Remove the break-away ring [10] from the mount-

ing plate [12].

41

Evolver 303 Dual Purge Robotic Atomizers - Maintenance

11. Pull down on the shroud [17] and slip it off the

applicator assembly to reveal the internal assembly

components. It may be necessary to carefully use a

flat head screwdriver between the shroud [17] and

the upper manifold [18] to pry the two apart.

12. Remove the five (5) air bolts [9] from the bottom

of the mounting plate [12]. Inspect the five (5)

o-rings [3] located within the air bolts [9] and replace

if necessary.

13. Remove the coil fluid tube [7] by unscrewing the

fluid fitting [4] from the valve manifold block [15].

14. Remove the cascade plug [16] from the mounting

plate [12] by unscrewing the set screw located on the

side of the mounting plate [12] in-line with the timer

markings. (For set screw location see Figure 17).

15. Slide the valve manifold block [15] and mounting

plate [12] off of the support rods [1] (see Figure 16).

16. Unscrew the five (5) support rods [1] from the

upper manifold [18] using an A11284-00 tool.

17. Remove the cascade [16] from the upper manifold

[18] by pulling straight down on the cascade [16]

(see Figure 16).

18. Remove the coil fluid tube [7] from the upper

manifold [18] by unscrewing the fluid fitting [4].

19. Remove the mounting plate [12] from the valve

manifold block [15] by unscrewing the three (3)

screws [8] located on the bottom of the mounting

plate [12].

20. Reassemble in reverse order making sure to align

the cascade wire plug timing mark with the timing

mark on the mounting plate [12] as shown in Figure

17. Remember to tighten the set screw called out

in Figure 17.

21. When placing the shroud [17] back onto the as-

sembly, make sure to mate the edge with the lip on

the shroud [17] with the upper manifold [18], and

fit the lip of the shroud [17] into the groove on the

upper manifold [18], as shown in Figure 16.