CognitiveTPG A760 User Manual
Page 87

A760 User Guide: Programming Supplement
Chapter 4: Programming commands
87
Revision F January 2010
Value of n
ASCII
Hex
Dec
Remote diagnostic item
Function
a
A6
166
Flash cycles tally
Clear flash cycles cut tally to 0
o
A7
167
Flash cycles tally
Return flash cycles cut tally, returns 10 bytes
¿
A8
168
Knife jams tally, 8 digit ASCII
Write to NVRAM
numeric, max 99,999,999
+
A9
169
Knife jams tally
Write to NVRAM, and print on receipt to verify
+
AA
170
Knife jams tally
Clear knife jams tally to 0
½
AB
171
Knife jams tally
Return knife jams tally, returns 10 bytes
¼
AC
172
Cover openings tally, 8 digit
Write to NVRAM
ASCIInumeric, max 99,999,999
¡
AD
173
Cover openings tally
Write to NVRAM, and print on receipt to verify
«
AE
174
Cover openings tally
Clear cover openings tally to 0
»
AF
175
Cover openings tally
Return cover openings tally, returns 10 ytes
B2
178
Max temperature tally
Reset max temperature reached value
|
B3
179
Max temperature tally
Return max temperature reached since it was reset,
returns 10 bytes
B4
180
Slip lines tally, 8 digit ASCII
Write to NVRAM
numeric, max 99,999,999
B5
181
Slip line tally
Write to NVRAM, and print on receipt to verify
B6
182
Slip lines tally
Clear slip lines tally to 0
B7
183
Slip lines tally
Return slip line tally, returns 10 bytes