AT&T AUDIX Networking 585-300-903 User Manual
Page 98

9-8
DCP Cabling and Administration
________________________________________________________________________________________________
________________________________________________________________________________________________
________________________________________________________________________________________________
Wd Fields
1-5 6 7 8 9 10 11 12 13 14 PROC
_
______________________________________________________________________________________
_
______________________________________________________________________________________
1 circuit0 * - - - 2 0 - 1 - 051
_
______________________________________________________________________________________
1 circuit1 * - - - 2 0 - 1 - 051
_
______________________________________________________________________________________
* This field may be 10 for DCP ports or 4 for converted RS-232 ports.
6. For each GPP equipment location, assign two appearances with the following characteristics (Proc
052, Word 1):
a. Device Type = Basic Set (Field 6 = 0)
b. Member = 0 (first appearance), then 1 (second appearance) (Field 7 = 0 or 1)
c. Extension Number = extensions assigned above (Field 8)
d. Call Appearance Number on this Set = 1 (Field 9 = 1)
e. Line Type = Prime Line (Field 10 = 1)
f. Alert Type = alert (Field 11 = 1)
g. Home Terminal = home terminal (Field 12 = 1)
h. Originating Call Appearance Only = not originating only (Field 13 = 0)
i. SAC Group = not a SAC member (Field 14 = 0 on R2V4 or later systems)
_
______________________________________________________________________________________
Wd Fields
1-5 6 7
8
9 10 11 12 13 14 PROC
_
______________________________________________________________________________________
_
______________________________________________________________________________________
l circuit0 0
0
xxxx0
1 1 1 1 0 0 052
_
______________________________________________________________________________________
l circuit0 0
1
xxxx1
1 1 1 1 0 0 052
_
______________________________________________________________________________________
l circuit1 0
0
xxxx2
1 1 1 1 0 0 052
_
______________________________________________________________________________________
l circuit1 0
1
xxxx3
1 1 1 1 0 0 052
_
______________________________________________________________________________________
7.
Auxiliary tone pack: A System 85 must have at least one SN253C auxiliary tone pack in every
module; this pack is administered using Proc 252, Word 2.
8.
Tone detector pack (remote networking configurations): A System 85 requires an SN255 tone
detector pack or an SN255B pack in applications requiring modems that use 2100 Hz answer tone
(such as the AT&T 2296, 2248, or 2224). Four tone detectors should be assigned on each SN255
board; the tone-detector trunk group is assigned in Proc 100, Word 1 as trunk type 100, and circuits
are assigned to this trunk group in Proc 150.