AT&T AUDIX Networking 585-300-903 User Manual
Page 201

AUDIX Network Testing
14-19
_
______________________________________________________________________________________
_
______________________________________________________________________________________
_
______________________________________________________________________________________
Step 2B: Testing the Local Connection
This tests the loop shown in Figure 14-15, Local Connection Test (DCP), Figure 14-16, Local Connection
Test (Switched RS-232), or Figure 14-17, Local Connection Test (Dedicated RS-232). In the case of
RS-232 direct, you must first arrange the cabling as shown in the figure.
1. Go to the
system : translation : machine : audix/amis/call delivery
form and press
ENTER
. The local machine profile should be displayed.
2. Make sure the network data phone number (or dial string) includes only the extension number
assigned to the networking hunt group. If using switched RS-232 channels with modems, the string
must still start with ATDT. If using direct RS-232 channels, the dial string should be blank.
3. If the phone number had to be changed, go to the
maintenance : audits : fp
form and run
a network data audit. This applies to R1V3 and R1V4 systems only; it is not necessary for R1V5 and
later systems.
4. Go to the
maintenance : network
form. Set select test to 1. Press
TAB
.
Set machine name to the name of the local machine. Press
CHANGE or RUN
. Wait for the result. If
the test is not successful, check the
system : log
and/or go to Flowcharts For Troubleshooting
the Network.