AUDIX Network Testing

14-19

_

______________________________________________________________________________________

_

______________________________________________________________________________________

_

______________________________________________________________________________________

Step 2B: Testing the Local Connection

This tests the loop shown in Figure 14-15, Local Connection Test (DCP), Figure 14-16, Local Connection
Test (Switched RS-232)
, or Figure 14-17, Local Connection Test (Dedicated RS-232). In the case of
RS-232 direct, you must first arrange the cabling as shown in the figure.

1. Go to the

system : translation : machine : audix/amis/call delivery

form and press

ENTER

. The local machine profile should be displayed.

2. Make sure the network data phone number (or dial string) includes only the extension number

assigned to the networking hunt group. If using switched RS-232 channels with modems, the string
must still start with ATDT. If using direct RS-232 channels, the dial string should be blank.

3. If the phone number had to be changed, go to the

maintenance : audits : fp

form and run

a network data audit. This applies to R1V3 and R1V4 systems only; it is not necessary for R1V5 and
later systems.

4. Go to the

maintenance : network

form. Set select test to 1. Press

TAB

.

Set machine name to the name of the local machine. Press

CHANGE or RUN

. Wait for the result. If

the test is not successful, check the

system : log

and/or go to Flowcharts For Troubleshooting

the Network.