beautypg.com

AT&T AUDIX Networking 585-300-903 User Manual

Page 140

background image

11-22

DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

________________________________________________________________________________________________

3. Procedure 100, Word 2 (for the digital side):

a. Enter the trunk group number (tgroup1) in Field 1.

b. Set the data rate for each speed optioned for the data modules in the modem pool in Fields 2

through 10.

NOTE

A data rate of 64 Kbps should always be translated for the modem pool in
addition to the data rates optioned on the data module; this will ensure that a
modem pool is selected when an incoming data call is directed to an AUDIX
DCP port. If 64 Kbps is not translated, the modem-pool setup may not work, or
may not recover after a failure.

c. Set Synchronous to 0 for asynchronous operation (Field 11 = 0).

d. Set Duplex to 0 for full duplex (Field 12 = 0).

e. Set Modem Pool Mode - Originate to 1 (Field 13 = 1).

f. Set Modem Pool Mode - Answer to 1 (Field 14 = 1).

g. Set Modem Pool - Modem Type to 1 (Field 15 = 1).

h. Set Modem Pool - Clock to 0 (Field 16 = 0).

i. Set Modem Pool - First Choice to 1 (Field 17 = 1).

j. Set Test Type to 0 (to turn off periodic on-line testing) or 1 (to allow periodic on-line testing)

(Field 18). Currently only R2V3 systems should have Field 18 set to 1. On other systems,
Field 18 should be 0.

k. Set Host Access Clock to 0 (Field 19 = 0).

_

______________________________________________________________________________________

Wd

1

2-10 11 12 13 14 15 16 17 18 19 PROC

_

______________________________________________________________________________________

_

______________________________________________________________________________________

2 tgroup1 * 0 0 1 1 1 0 1 $ 0 100

_

______________________________________________________________________________________

* = data rate (translate 64 Kbps in addition to optioned rates, usually 9600 bps)
$ = test type (see item j above)

4. Procedure 100, Word 1 (for the analog side):

a. Enter the trunk group number (tgroup2) in Field 1. A dial access code is not required (Fields 2

through 5).

b. Set Trunk Type to 101 (Field 6 = 101).

c. Set Dial Access Restriction to 0 (Field 7 = 0).

d. Set CO Line Appearance to 0 (Field 8 = 0).

_

______________________________________________________________________________________

Wd

1

2 3 4 5 6 7 8 PROC

_

______________________________________________________________________________________

_

______________________________________________________________________________________

1 tgroup2

101 0 0 100

_

______________________________________________________________________________________