beautypg.com

AT&T AUDIX Networking 585-300-903 User Manual

Page 102

background image

9-12

DCP Cabling and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

________________________________________________________________________________________________

ENHANCED MODE - PROCEDURE: 014, WORD: 1

BEARER CAPABILITY CLASS OF SERVICE - CALL OPTIONS

1. Bearer Capability COS: 6

DEFAULT CAPABILITIES

2.

Transport Mode: 0

Circuit

14.

Transport Mode: 0 Circuit

3.

Information Type: 0

Restrict

15. Information Type: 0 Restricted

16. Bearer Capability: 4 Mode 0

CALL TYPES AND ACTION TAKEN

4.

Voice: 0 Circuit switch the call

5. Voice Grade Data: 1 Insert a mode 2-to-analog modem pool facility

6.

Mode 0: 0 Circuit switch the call

7.

Mode 1: 0 Circuit switch the call

8.

Mode 2: 0 Circuit switch the call

9.

Mode 3: 0 Circuit switch the call

10. Unknown Digital: 0 Circuit switch the call

11.

Unknown Analog: 1 Insert a mode 2-to-analog modem pool facility

12.

Mode 3/2: 0 Circuit switch the call

13.

X.25: 0 Circuit switch the call

Connected to CC0 ON-LINE

MAJOR

MINOR

RUN TAPE

BUSY OUT

IN USE

WAIT

enter command: _

3 Data

5 Help

6 Field

7 Input

8 Cmds

Figure 9-6. Manager II Administration of DCP Port (Proc 014, Word 1)

3. The DCP extensions default to BCCOS 1. Change this to BCCOS 6 as shown in these examples.

This allows the DCP port to communicate with either a digital or analog outside facility.

A call to/from this port will be circuit switched unless it is voice-grade data or unknown analog. In
these cases, a modem pool will be inserted.