AT&T AUDIX Networking 585-300-903 User Manual
Page 105

DCP Cabling and Administration
9-15
_
______________________________________________________________________________________
_
______________________________________________________________________________________
_
______________________________________________________________________________________
6. Assign line appearances to the DCP equipment location. Make the entries as shown in Figure 9-9,
Manager II Administration for DCP Ports (Proc 052, Word 1). The extension shown in Field 8 is
only an example.
7. The first extension is assigned to Device Type 0 (Field 6) Member 0 (Field 7). Repeat step 6, only
use Device Type 0 Member 1 and assign a different extension to it.
8. Repeat steps 6 and 7 for the second DCP equipment location. Assign two other extension numbers to
Device Type 0 (Field 6) Members 0 and 1 (Field 7) for this equipment location.
If desired, you may display the extensions using Proc 052, Word 2.
ENHANCED MODE - PROCEDURE: 052, WORD: 1
MULTIAPPEARANCE TERMINAL/DATA MODULE - LINE APPEARANCE
TERMINAL EQUIPMENT LOCATION
DEVICE ID
1. Module: 0
6.
Device Type: 0 Basic Set
2. Cabinet: 1
7. Member (button): 0
3. Carrier: 1
EXTENSION APPEARANCE ID
4.
Slot: 18
8.
Extension: 32330
5. Circuit: 3
9. Line Appearance: 1
10.
Line Type: 1 Prime line
11.
Ringing Type: 1 Ringing
12.
Home Terminal: 1 Yes
13. Originating Only: 0 No
14.
SAC Group: 0 No
DISPLAY ONLY
15. Button Type: 1 Line appearance (052w1)
Connected to CC0 ON-LINE
♥
MAJOR
MINOR
RUN TAPE
BUSY OUT
IN USE
WAIT
enter command: _
3 Data
5 Help
6 Field
7 Input
8 Cmds
Figure 9-9. Manager II Administration for DCP Ports (Proc 052, Word 1)
9. After the extensions are assigned here, their BCCOS may be reset to 1. Go back to Procedure 000,
Word 3 and check if the BCCOS is still 6. If not, reset it to 6 if necessary. Check each of the
AUDIX networking extensions.