AUDIX Network Testing

14-11

_

______________________________________________________________________________________

_

______________________________________________________________________________________

_

______________________________________________________________________________________

Step 1C: Testing Remote Switched RS-232 Converted to DCP Connections

This test involves a path similar to Figure 14-10, Remote Connection Test (RS-232 Converted to DCP).

1. Go to the

system : translation : machine : audix/amis/call delivery

form.

Set machine name to the name of the remote AUDIX system. Press

ENTER

. The remote AUDIX

system’s machine profile should be displayed. If it is not displayed, it has not been assigned. Go to
Chapter 13, AUDIX System Administration, and create the remote system profile.

2. The network connection channel (or channel) should be blank unless channel 5 or channel 6 must be

used for the call (in which case, enter the channel number).

3. The network data phone number (or dial string) should be blank. Press

CHANGE or RUN

if any

changes were made.

4. Go to the

system : translation : network port

form. Make sure the

switched/dedicated field for the channel(s) is set to

s

. Press

CHANGE or RUN

if any changes were

made.

5. Go to the

maintenance : network

form. Make sure the channel to be tested is idle.

6. Go

to select test and enter

1

.

7. Go

to machine name and enter the name of the remote AUDIX system. Press

CHANGE or RUN

. Wait

for the result. If the test is not successful, check the

system : log

and/or go to Flowcharts For

Troubleshooting the Network.