AT&T AUDIX Networking 585-300-903 User Manual
Page 193

AUDIX Network Testing
14-11
_
______________________________________________________________________________________
_
______________________________________________________________________________________
_
______________________________________________________________________________________
Step 1C: Testing Remote Switched RS-232 Converted to DCP Connections
This test involves a path similar to Figure 14-10, Remote Connection Test (RS-232 Converted to DCP).
1. Go to the
system : translation : machine : audix/amis/call delivery
form.
Set machine name to the name of the remote AUDIX system. Press
ENTER
. The remote AUDIX
system’s machine profile should be displayed. If it is not displayed, it has not been assigned. Go to
Chapter 13, AUDIX System Administration, and create the remote system profile.
2. The network connection channel (or channel) should be blank unless channel 5 or channel 6 must be
used for the call (in which case, enter the channel number).
3. The network data phone number (or dial string) should be blank. Press
CHANGE or RUN
if any
changes were made.
4. Go to the
system : translation : network port
form. Make sure the
switched/dedicated field for the channel(s) is set to
s
. Press
CHANGE or RUN
if any changes were
made.
5. Go to the
maintenance : network
form. Make sure the channel to be tested is idle.
6. Go
to select test and enter
1
.
7. Go
to machine name and enter the name of the remote AUDIX system. Press
CHANGE or RUN
. Wait
for the result. If the test is not successful, check the
system : log
and/or go to Flowcharts For
Troubleshooting the Network.