System 75, generic 1, and generic 3 administration – AT&T AUDIX Networking 585-300-903 User Manual
Page 108

10-2
DCP Mode 1 Installation and Administration
________________________________________________________________________________________________
________________________________________________________________________________________________
________________________________________________________________________________________________
System 75, Generic 1, and Generic 3 Administration
Administration depends on whether the customer is using static (high-speed data only) or dynamic (voice
and high-speed data) switched 56 access.
NOTE
Any Generic 1 switches in a 56 Kbps network that includes a Generic 2 must be running at
least Issue 7.2 software.
•
Static Access: For static (high-speed data only) 56 Kbps switched access, the switch must be
administered as follows:
— Using the
add trunk-group
form, set the comm type to DATA and administer the switch for
wink in/wink out.
— Using the
change system-parameters features
form, set the
off-premise tone
detect
to 25.
— Using the
change ds1 circuit pack
form, set the
signaling mode
field to robbed-bit
and set either ZCS or B8ZS to match the CO.
•
Dynamic Access: For dynamic (voice and high-speed data) 56 Kbps switched access, the switch must
be administered as follows:
— Using the
add trunk-group
form, set the comm type to RBAVD, the baud rate (or bit rate) to
19.2, and administer the switch so it matches the central office trunk type.
— Using the
change system-parameters features
form, set the
off-premise tone
detect
to 25.
— Using the
change ds1 circuit pack
form, set the
signaling mode
field to robbed-bit
and set either ZCS or B8ZS to match the CO.