beautypg.com

Figure 9-3. audix to merlin ii connectivity, Audix – AT&T AUDIX Networking 585-300-903 User Manual

Page 94

background image

9-4

DCP Cabling and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

________________________________________________________________________________________________

AUDIX

AUDIX

AT&T

MERLIN II

DATA LINK

DATA LINK

VOICE PORTS

VOICE PORTS

SEE FIGURE 9-2

ACC

D8W

D8W

1

2

3

4

5

6

7

8

3
5
6

A

NON-DCP

SWITCH

Figure 9-3. AUDIX to MERLIN II Connectivity

4. Run the other ends of the D8W-87 cords to the MERLIN II (008D module). Plug them in to the

desired positions.

Any digital module (008D) jack position will work. The jack position determines the number
assigned to the AUDIX DCP data port.

5. Repeat steps 1 through 4 for each AUDIX-to-MERLIN II connection.