Setting up remote updates, Step 1: activitating the remote updates feature, Step 2: testing the remote updates feature – AT&T AUDIX Networking 585-300-903 User Manual
Page 208: Step 1: activating the remote updates feature

14-26
AUDIX Network Testing
________________________________________________________________________________________________
________________________________________________________________________________________________
________________________________________________________________________________________________
SETTING UP REMOTE UPDATES
Before activating the Remote Updates feature, check to see if calls between systems are toll calls. Also,
check the number of subscribers that already exist (
traffic : feature : day
form). If there are
much more than 100 local subscribers, the customer may want to wait for a low traffic period and/or
discount calling time before updates are activated.
Step 1: Activating the Remote Updates Feature
Perform the following steps to activate remote updates. To start with, activate remote updates only
between the local AUDIX machine and one remote machine.
1. Log in to the local AUDIX system and go to the
system : translation : remote
updates
form. Set allow full updates (y/n)? to
y
. Press
CHANGE or RUN
.
2. Go to the
system : translation : machine : audix/amis/call delivery
form.
Press
ENTER
to display the profile of the local system.
3. Set updates in (y/n)? to
y
. Set updates out (y/n)? to
y
. Press
CHANGE or RUN
.
4. Set machine name to the name of one of the remote AUDIX systems. Press
ENTER
. Repeat step 3.
5.
For R1V3 and R1V4 systems only: Go to the
maintenance : audits : fp
form and run a
network data audit. (This step is not necessary for R1V5 and later systems.)
6. Repeat steps 1 through 5 at the remote system you selected in step 4. Note that the ‘‘remote’’ system
becomes the ‘‘local’’ system once you log in to it.
Step 2: Testing the Remote Updates Feature
Demand Update Procedure
This procedure will cause a full update from the specified system only.
1. Go to the
system : translation : remote update
form. Set request full update from
(machine name) to the name of the remote AUDIX system and press
CHANGE or RUN
.
2. Go to the
maintenance : network
form and perform a connection test to the system specified
in step 1. If this is the first remote update from this system, the connect test could take a long time if
there are a large number of subscriber records to be sent.
3. Once the connect test has completed, go to Log In to the Remote Adjunct.