beautypg.com

Loopback testing for interlocated systems – AT&T AUDIX Networking 585-300-903 User Manual

Page 152

background image

12-4

DCP Mode 3 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

________________________________________________________________________________________________

LOOPBACK TESTING FOR INTERLOCATED SYSTEMS

If the AUDIX systems to be networked are at different locations (interlocated) and a serving office (SO)
will provide 64 Kbps service, you will need to test the connection between the local AUDIX system and the
64 Kbps serving office (SO), as shown in Figure 12-2, 64 Kbps Network Loop-Around Test. If you have
R1V7 software, you can do this via the

maintenance : network

form for the DCP ports (ports 1-4).

If you have an MPDM/M1* connected to ports 5 and 6, they may also be tested for 64 Kbps operation
using this form.

While a channel is in loopback mode, it will be unavailable to send information to remote systems or
receive information from remote systems. Incoming calls will be answered, but the calling system will be
unable to establish a connection; eventually it will drop the call and attempt to call back at its next
scheduled transmission time.

Also, if you put a channel in loopback mode, any active calls will be dropped. It is therefore recommended
before you perform this test you check the status of the channel. It is also not a good idea to perform this
test during peak traffic times.

1. Go to the

maintenance : network

form. Set select test to

8

to test a 64 Kbps network

connection. Press

TAB

to get to the channel field and then specify the channel (1-6) you want to

use for the test. Press

CHANGE or RUN

and wait for the result.

NOTE

If you have an MPDM/M1* between the AUDIX system and the PBX, you may also
test channels 5 or 6 (the RS-232 channels) for 64 Kbps operation.

2. Have the serving office place a call to the telephone number assigned to the channel you specified on

the

maintenance : network

form. If the test is successful, any data the serving office sends

over the AUDIX channel will be echoed back.

3. Go to the

maintenance : network

form. Set select test to

9

to take the channel out of

loopback mode. Press

TAB

to get to the channel field and then specify the channel (1-6) you want

to take out of loopback mode. Press

CHANGE or RUN

and wait for the result.