AUDIX System Administration

13-19

_

______________________________________________________________________________________

_

______________________________________________________________________________________

_

______________________________________________________________________________________

Form Fields

equipped

For each RS-232 channel cabled, set equipped to

y

.

synch/asynch

This field indicates the operating mode for the channel.

— If channel 5 is cabled through a modem or data set to the switch, enter an

a

. If it accesses a

synchronous modem pool once inside the switch, however, you should enter an s.

— If channel 5 is cabled directly to another system, enter an

s

.

Set the fields appropriately for channel 6. Assignments may be different than channel 5.

data rates

Assign data rates for each RS-232 channel. The default value for data rate (1): is 9600. For modems
that AT&T supports, the default value for both data rate (2): and data rate (3): is null (blank).

— If the RS-232 channel is not converted to DCP the data rate administered should match the modem

speed. The following values are typical:

If channel 5 is connected through the switch, set data rate 1 to

19200

. Leave data rate 2 and

data rate 3 blank.

If channel 5 is connected directly to another system, set data rate 1 to

64000

. Set data rate 2

to

56000

. Set data rate 3 to

19200

.

— If the RS-232 channel is converted to DCP, do one of the following:

Set data rate 1 to

56000

(synchronous) if a Modular Processor Data Module (MPDM), Model

M1*, is used on channel 5 for switched RS-232 converted to DCP mode 1. Leave data rate 2
and data rate 3 blank.

Set data rate 1 to

64000

(synchronous) if a Modular Processor Data Module (MPDM), Model

M1*, is used on channel 5 for switched RS-232 converted to DCP mode 3. Leave data rate 2
and data rate 3 blank.

Set data rate 1 to any value between

1200

and

19200

(asynchronous) if a 7400A or 7400B

data module is used on channel 5 for switched RS-232 converted to DCP mode 2. Leave data
rate 2 and data rate 3 blank.

Set the fields appropriately for channel 6.

switched/dedicated

RS-232 channels converted to DCP mode 1 or DCP mode 3 via an MPDM/M1* must be administered
as dedicated since these channels can only be used for incoming calls; they cannot be used for outgoing
calls.

— Enter

s

when the channel is connected to the switch through a modem or a 7400A or 7400B data

module.

— Enter

d

when the channel is connected directly to another system or if the channel is converted to

DCP mode 1 or DCP mode 3 via a MPDM/M1*, data module.