GF Signet 4150 Turbidimeter User Manual

Signet 4150 turbidimeter, English

background image

Signet 4150 Turbidimeter

3-4150.090

Rev N 11/12 English

*3-4150.090*

Speci¿ cations

Measurement Range

0 to 100.0 NTU or 0 to 1000.0 NTU

NTU = FNU = FTU

Accuracy
< 40 NTU:

±2% of reading or ±0.02 NTU

whichever is greater

> 40 NTU: ±5% of reading

Resolution

0.0001 NTU (below 10 NTU)

Response Time

Adjustable

Display

Multi-Line LCD with backlighting

Alarm Relays (2)

120 to 240 VAC, 2A Form C Relay

Current Output

Active 4 to 20 mA, 600 Ÿ

Digital Output

RS-485

Wetted Materials
• Tubing:

Vinyl

• Measuring Cuvette:

Borosilicate Glass

• Glass Washer Seal:

Silicone

• Pressure Regulator:

Polypropylene

FPM

316 Stainless Steel

Polyoxymethylene

(POM)

• Inlet Tube:

316 Stainless Steel

Maximum Inlet Pressure

Recommended 345 kPa (50 psi)

based on tubing connection provided

Pressure Regulator

Rated up to 200 psi

Flow Rate

0.1 L/m to 1 L/m

(0.026 GPM to 0.26 GPM)

Operating Temperature

1 °C to 50 °C (34 °F to 122 °F)

Sample Temperature Range 1 °C to 50 °C (34 °F to 122 °F)
Power Supply

100 to 240 VAC, 47 to 63 Hz, 80 VA

(12 to 24 VDC option available.

Contact

factory)

Insulation Rating

Double Insulated

Pollution Degree 2

Over voltage Category II

Altitude

2000 meters (6562 ft) maximum

Relative Humidity

Maximum 95% RH non-condensing

Enclosure Rating

Power Supply Box: NEMA 4X / IP66

Environmental Conditions Not recommended for outdoor use
Shipping Weight

2.5 kg (5.5 lb)

Standards and Approvals
CE
White Light version

Compliant to U.S. EPA 180.1

Infrared version

Compliant to ISO 7027

ETL Listed

UL 61010-1 and CSA C22.2

No.

61010-1

China

RoHS

For detailed information go to www.gfsignet.com

Description

The Signet 4150 Turbidimeter provides accurate and reliable water quality monitoring for municipal and industrial applications.
The 4150 uses the Nephelometric method to calculate the turbidity of a sample as it À ows through a viewing chamber. Models are
available that use white light technology as required by the U.S. EPA 180.1 standard, or select the models that use infrared technology
as required by ISO 7027.
Periodic calibration is mandatory with most turbidity systems, and the 4150 makes it fast and easy with sealed, reusable primary
calibration standards.
Two dry contact relays serve as high or low alarms, with programmable setpoints and time-based delays to prevent false alarms.
Additional features include a bright backlight for the display and a convenient holder for the cuvette during calibration.
An ultrasonic automatic cuvette cleaning system is standard for 0 - 100 NTU/FNU systems and optional for 0 - 1000 NTU/FNU systems.

Signet Turbidimeter

ENTER

Power Supply &
Wiring Terminals

English

This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and,
(2) This device must accept any interference received,
including interference that may cause undesired operation.