beautypg.com

Troubleshooting – ELRO HIS20S Security & home automation system EXPANDED USERS MANUAL User Manual

Page 60

background image

58

TROUBLESHOOTING

Smart Home Box not working – Power LED OFF

or flashing

1. Mains power failure – check if other electrical

circuits are operable.

2. Check that mains adaptor is plugged in and

socket is switched ON.

3. Check mains fuse in Plug has not blown.

4. Check that DC jack plug from mains adaptor is

connected in Control Panel.

5. Check fuse/MCB in Consumer Unit on the

circuit serving the Control Panel.

Note: Before replacing any fuses or resetting

the MCB, the cause of the failure should be

investigated and rectified.

Smart Home Box not accepting User Password

1. Pause between key depressions too long. Do

not pause for more than 5 seconds between

pressing keys.

2. Incorrect code entered.

3. Reset to factory defaults and reprogram system.

Smart Home Box not responding to detectors

1. Ensure that the ‘Code Learning’ from the

Detectors is correctly proceeded.

2. Ensure detector is within effective radio range

of Control Panel and equipment is not mounted

close to metal objects.

3. Detector battery low – replace battery.

Voice-Dialer not responding to Alarm

1. Telephone line not connected or faulty – check

phone line with another phone.

2. Set ‘Voice Dial’ to on.

3. Incorrect phone numbers programmed

4. Phone numbers disabled in dialing sequence

5. Alarm messages not recorded

6. Under Notification Setup of programming

instructions, set ‘Level Panic’ and ‘Level 1’ to

on.

Smart Home Box not contacting central

monitoring station service on alarm

1. Telephone line not connected or faulty – check

phone line with another phone.

2. Set ‘Monitor Center’ to on

3. Incorrect phone number for central monitoring

station service programmed

4. Incorrect system ID number for central

monitoring station service programmed.

5.

Central monitoring station service not

commissioned or signed up.

Smart Home Box not responding to Remote

Phone Access

1. Telephone line not connected or faulty – check

phone line with another phone

2. Set ‘TEL/SMS Remote’ to on

3. Incorrect

User

Password entered

Latch Key not responding when system

disarmed

1. Telephone line not connected or faulty – check

phone line with another phone

2. Set ‘Voice Dial’ to on

3. Set ‘Latchkey Report’ to on

4. No Latch-Key phone numbers programmed

5. Under Notification Setup of programming

instruction, set ‘Level 1’ of ‘TEL Phone 1’ to on

Full alarm condition occurs when system has

not been triggered by an intruder or is disarmed

1. Tamper

switch

activation

- check all detector battery covers to ensure

correctly fitted

- check Control Panel and Siren are securely

mounted to the wall and tamper switch is

closed

2. Panic alarm operated from a Remote Control or

Keypad

3. Jamming detection circuit operated