INTRODUCTION AND OVERVIEW


MULTIPLE USERS

The system allows for up to 7 Users and an

Administrator to be configured. This allows the

system Event Log to maintain a record of which users

have armed and disarmed the system. Each user will

have a different Password. In addition a 3 second

voice recorder facility enables the users name to be

recorded for use with the Latch-Key facility.

Only the Administrator has access to the programming

functions and is able to configure the system.

Note: Each Remote Control Units on the system will be

recorded.

SYSTEM ARMING

The system has a ‘Fully Arm’, ‘Holiday Arm’, ‘Night Arm’

and ‘Partial Arm’. ‘Fully Arm’ and ‘Holiday Arm’ will

arm all zones while ‘Night Arm’ and ‘Partial Arm’ will

only arm certain zones. The modes can be selected

for the following purpose:

Fully Arm

When the property is left un-occupied, the ‘Fully Arm’

mode will arm all zones to protect the entire property for

whole day long.

Holiday Arm

Holiday Arm is similar to fully arm mode except it

supports the schedule and event function of home

automation. If you are away from home for a holiday,

the ‘Holiday Arm’ will arm all zones to protect the entire

property while some set devices (e.g. On/Off receiver)

will be activated at set time per your request. This will

make your house looks as occupied.

Night Arm

The system could be configured such that during the

night, detection of movements in the armed zones

would automatically trigger the Green controls to turn

on the lights so you don’t have to fumble in the dark.

This mode also supports both schedule and event

function of home automation.

Note: Green control refers to the home automation

device that is built in receiver.

Partial Arm

The system could be configured such that at noon,

‘Partial Arm’ would arm only zones protecting the lower

floor and outbuildings leaving the upper floor free for

movement without triggering the alarm.


ZONES

The system incorporates 32 wireless Alarm Zones for

the connection of the system detectors that are used to

independently monitor different areas of the property.

In addition to standard intruder protection, each zone

may also be configured to operate in one of four

modes:

-

‘24-hour Intruder’ mode provides 24 hour intruder

protection for areas/zones where continuous

monitoring is required, (e.g. gun lockers).

- ‘Fire’ mode provides 24 hour monitoring of any

Fire/Smoke detectors incorporated into the system.

-

‘Intruder’ mode allows a zone to be monitored while

the system is armed. If a detector on a test zone

is triggered an entry will be recorded in the Event

Log and an alarm will occur.

-

‘Panic/PA’ mode provides 24 hour monitoring of any

emergency being occurred. Activation of any

panic switch will immediately initiate a Full Alarm

condition.

In addition there is the facility to connect 4 hard wired

zones to the Smart Home Box, each of which is fully

configurable with the same features as the wirefree

zones (1-32).

ENTRY/EXIT DELAY

When the system is armed with Exit-Delay enabled, no

alarm signal from any detector on an active zone will be

able to initiate an alarm until the Exit-Delay has expired.

This enables the system to be armed within the

property and allows time for user to exit property

without triggering an alarm. If Exit-Delay is disabled,

detection of movements by the detector will initiate an

alarm as soon as the system begins to arm.

The system Exit-Delay may be configured among 10,

30 seconds, 1, 2 and 4 minutes or off completely.

Similar mechanism works for Entry-Delay except it’s for

user entering the property. This period of time can be

used to disarm the system before an alarm condition

occurs.

The Entry-Delay for all zone may be configured among

10, 30 seconds, 1, 2 and 4 minutes or off completely.