beautypg.com

Testing the pir detectors – ELRO HIS20S Security & home automation system EXPANDED USERS MANUAL User Manual

Page 13

background image

11

Set the required sensitivity detection using DIP2 of

SW2 as follows:

ON high sensitivity detection

OFF low sensitivity detection

Note: The higher the sensitivity detection the less

movement will be necessary before the PIR

detector will trigger the alarm.

3. The setting of the DIP1 & DIP2 of SW2 can be

distinguished from the LED indication as follows:

On/Off

Selection

DIP1 of

SW2

DIP2 of

SW2

Trigger reaction of LED

High

Sensitivity

LED will be on once.

It implies high

sensitivity.

ON Walk

Test

mode

Low

Sensitivity

LED will flash twice. It

implies low sensitivity.

OFF Normal

mode

High/Low

Sensitivity

LED does not light up.

In summary, the setting of DIP1 & DIP2 of SW2 is

concluded as below:

SW2 DIP1

DIP2

ON Walk

Test

Mode

High

sensitivity

OFF Normal

Mode

Low

sensitivity

4. Connect the 1/2 3.6V Lithium battery to the battery

spring.

Note: When the battery is connected, the LED

behind the lens will flash for 2-3 minutes as

warming-up duration until the PIR has stabilized

when the LED will then stop flashing and turn OFF.

5. In normal mode, remove the rear cover of the PIR

detector. The Detector’s LED will illuminate and the

Smart Home Box should beep. It is because the

tamper switch fitted on the Detector has been

activated.

6. When the Detector is fully installed i.e. battery

cover is refitted; the Detector will not detect

movement for approximately 2 minutes after each

activation. (This feature is present to conserve

battery power and maximize the battery life).

7. In order to communicate with the Smart Home Box,

the ID code of the Detector needs to be learned by

the Smart Home Box. To proceed with ID code

learning.

a. Set the Smart Home Box into ‘3. Security

Sensor Zone’ and press .

b. Select ‘3-1 Wireless Sensor Zone’ and

press .

c. ‘Input (01-32) Sensor Zone’ and press .

d. An indication of ‘:1 Learning ID’ will be shown

and press .

By pressing tamper switch located adjacent to the

PCB on the Detector will emit the ID code to the

Smart Home Box instantly.


8. For quick start, jumper link (S2) will quick start the

battery this will take approx. 2 minutes. By
placing the jumper link (S2) into position, the LED
adjacent to the (S2) jumper link will become
illuminated, this implies the battery start up has
been completed. It is important to remove the
jumper link (S2) after this has been observed to
save battery power.




Jumper link (S2)


Note
: On first battery start up, because of the
nature of the battery protection the battery may
incur a low battery status and may not start up
straight away, but will automatically start within 10
minutes.

Note: Only one of pins of Jumper link (S2) will be
inserted in position as factory default setting.


TESTING THE PIR DETECTORS

Ensure that the system is in Test Mode.

With the PIR detector set in Test mode and mounted in

position on the wall, allow 2-3 minutes for the detector

to stabilize before commencing the Walk Test.