Burkert Type SE56 User Manual
Page 23
TECHNICAL MANUAL
Rev.
Pagine
23/52
Filling By
Checked By
03
PROFIBUS DP MODULE- DATA LINK
DESCRIPTION
Document Data
Date
Date
File name
ProfibusDP_emanual_Burkert_04.doc
19/03/08 19/03/08 19/03/08
23
8
specific weight in use
9
additional output 3 present
10 additional output 4 present
11 output 4..20 mA 2 present
12 RS232
present
13 batching
functions
active
14 output 4..20 mA 2 present
15 RS485
present
byte 14: (8 bits integer) current language set in the Flow meter
Format of the returned data:
0(dec) = English
1(dec) = Italian
2(dec) = French
3(dec) = Spanish
NOTE: For reading the type of language it is first necessary to send to the slave the relative command, see
the INDEX Output = 10 (below in this section) and then read the type of language in the byte 4.
INDEX Input = 34(dec) Data and Time of the Flow meter ( only for ML 210)
byte 0: (8 bits integer) current INDEX Input
byte 1: (8 bits integer) current INDEX Output
bytes 2-5 (32 bit long integer, MSB first) clock expressed in minutes starting from 01-01-1992
NOTE: The date and time are expressed with a 32 bit integer containing the number of minutes elapsed
since 01-01-1992. To calculate the date starting from this number, see the programming examples in the
section 4.0 PROGRAMMING ALGORITMS of this manual.
INDEX Input = 40(dec) Batch Data
byte 0: (8 bits integer) current INDEX Input
byte 1: (8 bits integer) current INDEX Output
bytes 2-3: (2 bytes 16 bit unsigned integer, MSB first) number of batch processes done for this batch
memory.
bytes 4-5: (2 bytes 16 bit unsigned integer, MSB first) value of the batch safety timer expressed in tenths of
seconds.
bytes 6-9: (4 bytes 32 bits unsigned long integer, MSB first) batch quantity value expressed in the same
units and with the same decimal digits of the volume counters
byte 10: (8 bits integer) batch status:
Format of the returned data: 1 byte containing the batch process state:
0(dec) = batch process is correctly terminated (pre-set quantity reached).
1(dec) = batch process is running (the valve is opened and the counters are running).
2(dec) = batch process is suspended (the valve is closed before the pre-set quantity is reached).
NOTE: The recipe utilized for this configuration is the 00 in the meter and the name utilized for this recipe is
PROFIBUS.
INDEX Input = 42(dec) Batch Parameters
byte 0: (8 bits integer) current INDEX Input