Signal source, Trigger type – B&K Precision 2532B - Manual User Manual
Page 61

61
The feature is very useful because you can see the events that led
up the trigger point. Everything to the right of the trigger point is
the post-trigger information. The amount of delay range (pre-
trigger and post-trigger information) available is dependent on the
sweep speed selected.
Signal Source
You can use the Trigger Source options to select the signal that the
oscilloscope uses as a trigger. The source can be any signal connected to a
channel BNC, to the EXT TRIG BUS, or the AC power line (available only
with Edge Trigger).
Trigger Type
The scopes have five trigger types: Edge, Video, Pulse, Slope, and
Alternative.
Edge Trigger
Use Edge triggering to trigger on the edge of the oscilloscope input signal
at the trigger threshold.