B&K Precision 2532B - Manual User Manual
Page 161

161
Measure signal frequency
●
Input the signal to channel 1.
●
Press the “AUTO” button.
● Press the “MEASURE” button to see “auto Measure Menu”.
● Press the top option button.
● Press the “Time” option button to enter the “Time Measure menu”.
● Press the “Source” option button to select input signal channel.
●
Press the “Type” option button to select “Freq”
.
The corresponding icon and measure value will display on the
third option area.
Measure signal peak-to-peak amplitude
● Press the “MEASURE” button to display “auto measure menu”.
● Press the top second option button.
●
Press the “Voltage” option button to enter the “Voltage measure menu”.
● Press the “Source” option button to select input signal channel.
● Press the “Type” option button to select “Vpp”.
The corresponding icon and measure value will display on the third option
area.