Triggering on video lines, Application of x-y function, Pplication of – B&K Precision 2532B - Manual User Manual
Page 168: Unction

168
Triggering on Video Lines
To trigger on the video lines, follow these steps:
1. Press the “TRIGGER MENU” button to see the trigger menu.
2. Press the top “option” button and select “Video”
3. Press the “Sync” option button and select “Line Num” and turn the
universal knob to set a specific line number.
4. Press the “Standard” option button and select “NTSC”.
5. Turn the “Time/Div” knob to see a complete video line across the
screen.
6. Turn the “Volts/Div” knob to ensure that the entire video signal is
visible on the screen.
Application of X-Y Function
Viewing Impedance Changes in a Network
Connect the oscilloscope to monitor the input and output of the circuit
To view the input and output of the circuit in an XY display, follow these
steps:
1. Press the “CH 1” MENU button and set the Probe option
attenuation to 10X.
2. Press the “CH 2” MENU button and set the Probe option
attenuation to 10X.
3. Set the switch of the probe to 10X.