beautypg.com

Extron Electronics SMD 101 User Guide User Manual

Page 90

background image

The web-based user interface explains what is retained by each reset. The following table
outlines configuration settings and files affected by the SIS command and rear panel resets.
In general, configuration settings and files can be:

Retained (not affected by the reset).

Reset to factory (the original factory firmware replaces the current).

Erased (the configuration settings or files are deleted).

Device Reset From:
SIS
Command

Rear Panel

Web-
based User
Interface

Firmware User

File
System

Network
Shares

Device
Config

Passwords IP

Settings

Factory
Firmware (one
power cycle)

n/a

Mode 1
(see note,
below)

n/a

Factory

Retained Retained Retained Retained

Retained

Network (IP
settings) reset

n/a

Mode 4

n/a

Retained

Retained Reset

Retained Retained

Reset

Flash Reset

E

ZFFF

}

n/a

n/a

Retained

Erased

Retained Retained Retained

Retained

System reset
(Factory
defaults).
User files
and settings
Retained.

E

ZXXX

}

n/a

Reset device
settings to
default, but
retain user
files and all
IP settings

Retained

Retained Reset

Reset

Retained

Retained

Reset device
settings and
delete user
files.
Retain IP
settings.

E

ZY

}

n/a

Reset device
settings
to default,
delete user
files, retain
IP settings

Retained

Erased

Reset

Reset

Reset

Retained

Absolute
Reset:
settings,
files, and IP
settings.

E

ZQQQ

}

Mode 5

Reset device
settings,
delete
internal user
files, and
Reset all IP
settings

Retained

Erased

Reset

Reset

Reset

Reset

NOTE: A browser refresh is required to see results of a reset.