Reset device, Eset using the web-based user interface (see, Reset – Extron Electronics SMD 101 User Guide User Manual
Page 48: Device, Or using the web-based user interface (see
To set, change, or clear a user password you must be logged on as an admin.
1.
Click
Clear
to clear a previous password, then type a password in the
User
Password:
field. If this is the first time a password is set, type the password in the
User
Password:
field.
2.
Duplicate the password in the
Confirm
Password:
field.
3.
Click
Save
.
Reset Device
Provides several options to reset the SMD 101 if hardware or software conditions require.
NOTE: Proceed with caution. Some reset modes intentionally delete all user files,
media content, and settings from internal memory.
Figure 39.
Device Reset, Reset Options
•
Reset Device settings to default — Resets all hardware and software to default
condition, but retains user files and IP settings for communication.
•
Reset Device settings and delete internal user files (Retains all IP settings) —
Resets all hardware and software to default condition, deletes user files stored in
internal memory, and retains IP settings for communication.
•
Reset Device settings, delete internal user files, and reset all IP settings —
Resets all hardware and software to default condition including IP settings.
NOTE: If the control PC is connected via the Ethernet port, communications is
broken. Use the default IP address (192.168.254.254), the front panel config port,
or the rear panel RS-232 port to reconnect.
To select a reset, click the button to the left of the desired option. The radio button lights.
Click
Apply
to begin the reset. See the
on page 83 for a
comparison of the reset modes.
SMD 101 • Web-based User Interface