Command and response tables, Basic sis commands, Of the – Extron Electronics SMD 101 User Guide User Manual
Page 73: Section
Command and Response Tables
Basic SIS Commands
Command
ASCII command
(host to device)
URL Encoded
(web)
Response
(device to host)
Information requests
Firmware version
Q/q
*Q
X1!]
Firmware and build
version
*Q/q
*Q
X1!]
Kernel firmware and build
**Q/q
**Q
X1!]
ID messaging version
***Q/q
***Q
X1!]
Verbose version info
0Q/0q
0Q
Sum of 2Q‑3Q‑4Q
]
Firmware version
1Q/1q
1Q
X1!]
Bootstrap version
2Q/2q
2Q
X1!]
Factory firmware version
3Q/3q
3Q
X1!
plus kernel version,
model number, and load
date
]
Updated firmware version
4Q/4q
4Q
X1!
plus kernel version,
model number, and load
date
]
NOTE: An asterisk (*) after the version number indicates the currently running version. Question marks (?.??)
indicate that only factory firmware is loaded. A caret (^) indicates the firmware version that should be
running, but a Mode 1 reset was executed and the default factory firmware is running. An exclamation point
(!) indicates corrupted firmware.
General Information
I/i
SMD •101
Query part number
N/n
N
60– 1305‑01
]
Query model name
I/i
I
SMD •101
]
Query model description
2I/i
2I
Streaming•Media•Decoder
Query system memory
usage
3I
3I
#Bytes used out of
#KBytes
]
View system processor
usage
11I
11I
Returns a percentage of total.
View system processor
idle
12I
12I
Returns a percentage of total.
View eth0 link status
13I
13I
Current link state, speed, and
mode.
View telnet connections
E
CC
}
n
]
n=number of active IP
connections.
Set verbose mode
E X2@
CV
}
Vrb X2@]
View verbose mode
E
CV
}
X2@]
NOTES:
X1!
= Version number
Firmware version number to second decimal place (
x.xx)
Version and Build number adds four digits (
x.xx.xxxx)
to the Version number
X2@
= Verbose/Response mode
0=clear/none (default for telnet connections)
1=verbose mode (default for RS-232 host control)
2=tagged responses for queries
3=verbose mode and tagged responses for queries
NOTE:
If tagged responses is enabled, all read commands return the data, the same as setting
the value does (Example: command: E CV} Response: Vrb3 ]).
01-16-2014: SIS tables updated to Product Proposal Rev 3.01, dated 08-08-2013.
02-11-2014: SIS tables updated from QA and Ian reviews. Also legends and notes modified to
match each other.
02-26-2014: Final round of QA reviews and Ian corrections based on those reviews.
67