Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional
Description
Port Assignment
NOTES:
•
Duplicate
port#
assignments are not permitted (for example, the telnet and web port assignment cannot be the
same) and will return the
E13
error.
•
Remapping of
port#
assignments must be to ports 1024 or higher (unless resetting to the default port number or
disabling the port by setting it to 0).
Telnet port
Set telnet port map
E
[port#]MT
}
Pmt[port#]
]
Set the telnet port.
Reset telnet port
map
E
23MT
}
Pmt 00023
]
Reset the telnet port to the
default value (23).
Disable telnet port
E
0MT
}
Pmt 00000
]
Disable the telnet port.
View telnet port map
E
MT
}
[port#]
]
View the currently set telnet
port.
Web port
Set web port map
E
[port#]MH
}
Pmh[port#]
]
Set the web port.
Reset web port map
E
80MH
}
Pmh 00080
]
Reset the web port to the
default value (80).
Disable web port
E
0MH
}
Pmh 00000
]
Disable the web port.
View web port map
E
MH
}
[port#]
]
View the currently set web
port.
SNMP port
Set SNMP port map
E A[port#]PMAP }
Pmap A[port#]
]
Set the SNMP port.
Reset SNMP port
map
E A 161PMAP }
Pmap A 00161
]
Reset the SNMP port to the
default value (161).
Disable SNMP port
E A 0PMAP }
Pmap A 00000
]
Disable the SNMP port.
View SNMP port
map
E A PMAP }
[port#]
]
View the currently set SNMP
port.
SSH port
Set SSH port map
E B[port#]PMAP }
Pmap B[port#]
]
Set the SSH port.
Reset SSH port map
E B 22023PMAP }
Pmap B 22023
]
Reset the SSH port to the
default value (22023).
Disable SSH port
E B 0PMAP }
Pmap B 00000
]
Disable the SSH port.
View SSH port map
E B PMAP }
[port#]
]
View the currently set SSH
port.
SSL port
Set SSL port map
E S[port#]PMAP }
Pmap S[port#]
]
Set the SSL port.
Reset SSL port map
E S 443PMAP }
Pmap S 00443
]
Reset the SSL port to the
default value (443).
Disable SSL port
E S 0PMAP }
Pmap S 00000
]
Disable the SSL port.
View SSL port map
E S PMAP }
[port#]
]
View the currently set SSL
port.
Command and Response Table for Basic SIS Commands (continued)