beautypg.com

SENA ProBee-ZE20S-SEME User Manual

Page 99

background image

ProBee-ZE20S-SExx User Guide Rev 1.8

99

Response

OK

OK or ERROR

Default

01-01-2000/00:00:00

Range

01-01-2000/00:00:00 - 02-07-2136/06:28:15

7.14.9 AT+MSGETLAST or AT+MGL

Description

Send ‘Get Last Message’ command(Messaging cluster) to destination node.

(client-side command)

Execute

AT+DEST=

,

AT+MSGETLAST

Response

OK or ERROR

7.14.10 AT+DLLIST or AT+DLT

Description

Show DRLC Event List.

Execute

AT+DLLIST?

Response

event ID|clss|gr|dura|cr|cool(sp)|heat(sp)|av|du|ct|start time

..

OK

7.14.11 AT+DLSTARTTIME or AT+DST

Description

Get/Set DRLC Start Time. This value will be used in AT+DLUPDATE and

AT+DLGETSCH. The format of time is determined by ATU value.

Execute

AT+DLSTARTTIME?

AT+DLSTARTTIME=

Response

OK

OK or ERROR

Default

01-01-2000/00:00:00

Range

01-01-2000/00:00:00 - 02-07-2136/06:28:15

7.14.12 AT+DLUPDATE or AT+DLU

Description

Update DRLC Event.

Execute

AT+DLUPDATE=,,,

point>,

load

adjustment

percentage>,

cycle>,

control>

Response

OK or ERROR

7.14.13 AT+DLREPORTES or AT+DRE

Description

Send ‘Report Event Status’ command(DRLC cluster) to destination node. (client-

side command)

Execute

AT+DEST=

,