Example3) Set Partner Key Exchange from ProBeeSEID(end-device) to ProBeeSEME(end-device)
#Screen of ProBeeSEID(end-device)
AT+CBKEPARTNER=AB74,01
# You can also use AT+DEST for setting
# destination node
CBKE PARTNER DEST: 0xAB74, EP: 0x01, RESULT: 0x00
OK
Key Table of ProBeeSEID is changed as follows:
#Screen of ProBeeSEID(end-device)
AT+KEYTABLE
NETWORK KEY: FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
LINK KEY TABLE
#|IEEE_ADDRESS |TYPE|AUTH|KEY
*|000195AABBCC0000|LINK|YES |C9AF9B248454840FDD80AAFBBAA4028F
0|000195AABBCC0002|LINK|YES |D0B64ED5A1D33F4CD28EE3BAE6B9E3A7
# Key Table No.0 is added
# Partner key exchanged successfully
2/6 ENTRIES USED
OK
Key Table of ProBeeSEME is also changed as follows:
#Screen of ProBeeSEME(end-device)
AT+KEYTABLE
NETWORK KEY: FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
LINK KEY TABLE
#|IEEE_ADDRESS |TYPE|AUTH|KEY
*|000195AABBCC0000|LINK|YES |5C500189361BC97EB1F50AE429B98565
0|000195AABBCC0001|LINK|YES |D0B64ED5A1D33F4CD28EE3BAE6B9E3A7
# Key Table No.0 is added
# Partner key exchanged successfully
2/6 ENTRIES USED
OK