SENA ProBee-ZE20S-SEME User Manual
Page 77

ProBee-ZE20S-SExx User Guide Rev 1.8
77
autonomously send readings periodically. A Metering end device may also be capable of communicating
certain status indicators (e.g. battery low, tamper detected).
6.4.3.1 Cluster Support
Table 6-8 ProBeeSEME Cluster Support
Server Side
Client Side
Basic
Time
Identify
Messaging
Metering
Key establishment
Key establishment
6.4.3.2 Attributes
Table 6-9 ProBeeSEME Attributes
Cluster
ID
Cluster name
Attribute
ID
Attribute name
Type
0x0000 Basic
0x0000 ZCL version
INT8U
0x0001 Application version
INT8U
0x0002 Stack version
INT8U
0x0003 Hardware version
INT8U
0x0007 Power source
ENUM8
0x0011 Physical environment
ENUM8
0x0012 Device enabled
BOOLEAN
0x0013 Alarm mask
BITMAP8
0x0014 Disable local config
BITMAP8
0x0003 Identify
0x0000 Identify time
INT16U
0x0702 Metering
0x0000 Current summation delivered
INT48U
0x0001 Current summation received
INT48U
0x0002 Current
max
demand
delivered
INT48U
0x0003 Current max demand received
INT48U
0x0004 Dft summation
INT48U
0x0200 Status
BITMAP8