same address or a device leaves the network and later joins.
Execute
AT+SHORTADDR?
Response
OK
7.3.3
AT+ADDRDISCOVERY or AT+AD
Description Get the corresponding address of a node whose long or short address is known.
Execute
AT+ADDRDISCOVERY=
Response
OK
OK
7.3.4
AT+OPCH or AT+OC
Description
Get the operating channel number used for transmitting and receiving between
RF modules. Uses 802.15.4 channel numbers. A value of “0” means the device
has not joined a PAN and is not operating on any channel.
Execute
AT+OPCH?
Response
OK
7.3.5
AT+OPPANID or AT+OI
Description
Get the operating 16-bit PAN ID. If PAN ID is set specific value not 0s, operating
PAN ID will equal designated PAN ID. A value of “FFFF” means the device is not
joined a network.
Execute
AT+OPPANID?
Response
OK
7.3.6
AT+OPEPID or AT+OE
Description
Get the operating 64-bit extended PAN ID. A value of “FFFFFFFFFFFFFFFF”
means the device is not joined a network.
Execute
AT+OPEPID?
Response
OK
7.3.7
AT+VERSION or AT+VR
Description
Get firmware version of the module. The firmware version returns a form of
“SExxvx.x”.
Execute
AT+VERSION?