SENA ProBee-ZE20S-SEME User Manual
Page 90

ProBee-ZE20S-SExx User Guide Rev 1.8
90
7.11 Firmware Upload and Help
7.11.1 AT+BOOTLOAD or AT+BL
Description
Start bootloader to upload firmware. (blank: local, 1: passthru)
The device leaves the AT command line and enters the bootloader menu for
uploading new ProBee firmware. There’s no restrict to use local upload but a
sleepy end-device cannot upload to remote node over the air. The current UART
should be set 115200bps, 8 data bits, no parity, 1 stop bit and none flow control.
Execute
AT+BOOTLOAD
AT+BOOTLOAD=
Response
Bootloader menu
…
Serial upload complete
Please start .ebl upload image ...
Start cloning ...
Bootloader menu
…
Bootload Complete!
7.11.2 AT+HELP or AT+HP
Description
Show all the available commands
Execute
AT+HELP
Response
Available AT Commands
…
OK
7.12 Smart Energy Commands
7.12.1 AT+ATTR or AT+AR
Description
Show all attributes of local node.
Execute
AT+ATTR?
AT+ATTR=
Response
clus|attr|data(cluster name)
…
OK
7.12.2 AT+INFO or AT+IF
Description
Show Smart Energy device information
Execute
AT+INFO?
Response
Security Level:
End-point count:
End-point No.
Client-side cluster:
Server-side cluster:
...