SENA ProBee-ZE20S-SEME User Manual
Page 65

ProBee-ZE20S-SExx User Guide Rev 1.8
65
5.4.9
Reading Attribute
User can read attribute of local node or remote node by running the AT command as below:
AT+SREAD can be used for reading attribute of local node.
AT+CREAD can be used for reading attribute of remote node.
User should set destination address by AT+DEST before running AT+CREAD.
Destination node must implement corresponding attribute and cluster.
Example) Read attribute of local node.
#Screen of ProBeeSESI(coordinator)
AT+SREAD=0000,0007
# Read device attribute
# Basic cluster(0x0000),
# Power source attribute(0x0007)
2
# Unlocked
OK
# Response
Example) Read attribute of remote node.
#Screen of ProBeeSEID(end-device)
AT+DEST=0000,01
# Set destination node address
OK
# Response
AT+CREAD=0702,0000
# Read attribute of destination node
# Metering cluster(0x0702),
# Current Summation delivered attribute(0x0000)
00 00 00 00 00 00
# 5-byte value
OK
# Response
5.4.10 Writing Attribute
User can write attribute to local node or remote node by running the AT command as below:
AT+SWRITE can be used for writing attribute to local node.
AT+CWRITE can be used for writing attribute to remote node.
User should set destination address by AT+DEST before running AT+CWRITE.
Destination node must implement corresponding attribute and cluster.